The DOI matches its Crossref record.
Characterization of Inwardly Rectifying K + Channel in Human Cardiac Myocytes: Alterations in Channel Behavior in Myocytes Isolated From Patients With Idiopathic Dilated Cardiomyopathy
Abstract
Background Little is known about the characteristics of the inwardly rectifying K + channel ( I K1 ) and the influence of preexisting heart disease on the channel properties in the human heart. Methods and Results We studied the characteristics of cardiac I K1 in freshly isolated adult human atrial and ventricular myocytes by using the patch-clamp technique. Specimens were obtained from the atria and ventricles of 48 patients undergoing cardiac surgery or transplantation and from four explanted donor hearts. The action potential in ventricular myocytes exhibited a longer duration (391.4±30.2 milliseconds at 90% repolarization, n=10) than in atrium (289.4±23.0 milliseconds, n=18, P <.001) and had a fast late repolarization phase (phase 3). The final phase of repolarization in ventricle was frequency independent. Whole-cell I K1 in ventricle exhibited greater slope conductance (84.0±7.9 nS at the reversal potential, E K ; n=27) than in atrium (9.7±1.2 nS at E K ; n=8, P <.001). The steady-state current-voltage (I-V) relation in ventricular I K1 demonstrated inward rectification with a region of negative slope. This negative slope region was not prominent in atrial I K1 . The macroscopic currents were blocked by Ba 2+ and Cs + . The channel characteristics in ventricular myocytes from patients with congestive heart failure after idiopathic dilated cardiomyopathy (DCM) exhibited distinct properties compared with those from patients with ischemic cardiomyopathy (ICM). The action potential in ventricular myocytes from patients with DCM had a longer duration (490.8±24.5 milliseconds, n=11) compared with that for ICM (420.6±29.6 milliseconds, n=11, P <.01) and had a slow repolarization phase (phase 3) with a low resting membrane potential. The whole-cell current slope conductance for DCM was smaller (41.2±9.0 nS at E K , n=7) than that for ICM (80.7±17.0 nS, n=6, P <.05). In single-channel recordings from cell-attached patches, ventricular I K1 channels had characteristics similar to those of atrial I K1 ; channel openings occurred in long-lasting bursts with similar conductance and gating kinetics. In contrast, the percent of patches in which I K1 channels were found was 34.7% (25 of 72) of patches in atrium and 88.6% (31 of 35) of patches in ventricle. Single I K1 channel activity for DCM exhibited frequent long-lasting bursts separated by brief interburst intervals at every holding voltage with the open probability displaying little voltage sensitivity (≈0.6). Channel activity was observed in 56.2% (18 of 32) of patches for DCM and 77.4% (24 of 31) of patches for ICM. Similar results were obtained from atrial I K1 channels for DCM. In addition, channel characteristics were not significantly different between ICM and explanted donor hearts (donors). I K1 channels in cat and guinea pig had characteristics virtually similar to those of humans, with the exception of lower open probability than that in humans. Conclusions These results suggest that the electrophysiological characteristics of human atrial and ventricular I K1 channels were similar to those of other mammalian hearts, with the possible exception that the channel open probability in humans may be higher, that the whole-cell I K1 density is higher in human ventricle than in atrium, and that I K1 channels in patients with DCM exhibited electrophysiological properties distinct from I K1 channels found in patients with ICM and in donors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416
Courtemanche, M., Ramirez, R. J., & Nattel, S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.1.h301 · Cited by 1,218
Winslow, R. L., Rice, J., Jafri, S., Marbán, E., & O’Rourke, B. (1999) · Circulation Research · doi:10.1161/01.res.84.5.571 · Cited by 797
Electrophysiological remodeling in hypertrophy and heart failure
Tomaselli, G. (1999) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00017-6 · Cited by 748
Pathophysiology and Prevention of Atrial Fibrillation
Allessie, M. A., Boyden, P. A., Camm, A. J., Kléber, A. G., Lab, M. J., Legato, M. J., Rosen, M. R., Schwartz, P. J., Spooner, P. M., Van Wagoner, D. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.5.769 · Cited by 726
Metadata
- Authors
- Koumi, S.-I., Backer, C. L., & Arentzen, C. E.
- Venue
- Circulation
- Published
- 1995-07-15
- Volume
- 92
- Issue
- 2
- Pages
- 164-174
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2090077994
- Cited by
- 172
- References
- 0
- FWCI
- 7.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Inwardly Rectifying K + Channel in Human Cardiac Myocytes: Alterations in Channel Behavior in Myocytes Isolated From Patients With Idiopathic Dilated Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.92.2.164
- The paper
- Koumi, S.-I., Backer, C. L., & Arentzen, C. E. (1995). Characterization of Inwardly Rectifying K + Channel in Human Cardiac Myocytes: Alterations in Channel Behavior in Myocytes Isolated From Patients With Idiopathic Dilated Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.92.2.164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.