The DOI matches its Crossref record.
Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis
Abstract
Background Recent findings suggest that acoustic cavitation is responsible for acceleration of thrombolysis by ultrasound (US) energy. It is known that albumin microbubbles lower the threshold of acoustic cavitation production. Methods and Results The present study was designed to determine whether the presence of albumin microbubbles used for echo-contrast material (Albunex) can further accelerate fibrinolysis by US. Artificial thrombus was produced by Chandler’s loop method with blood extracted from a healthy subject. Urokinase (UK, 1200 IU/mL) was added to the artificial thrombi placed in test tubes. Each thrombus was exposed to US (170 kHz) at a distance of 1.2 cm for a total of 60 seconds at an intensity of 0.5 W/cm 2 at intervals of 2 seconds on and 4 seconds off. Echo-contrast material (0.6×10 6 microspheres per mL) or 5% albumin (for control) was circulated near the thrombus at a rate of 1 mL/min during the US exposure. Fibrinolysis was later determined by percentage of weight loss of thrombus after 60 minutes of incubation (n=15). Fibrinolysis with UK alone was 26.6±4.8%. Fibrinolysis with UK+US treatment was 33.3±5.8%. Further increase of fibrinolysis to 51.3±7.7% occurred in the presence of Albunex (UK+US+Albunex). Statistical differences were obtained between all these groups (ANOVA). Conclusions The presence of the echo-contrast agent induced further acceleration of thrombolysis by US energy. It is suggested that this diagnostic echo-contrast material can be used as an alternative therapeutic US drug enhancer for thrombolysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Microbubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Metadata
- Authors
- Tachibana, K., & Tachibana, S.
- Venue
- Circulation
- Published
- 1995-09
- Volume
- 92
- Issue
- 5
- Pages
- 1148-1150
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2126485399
- Cited by
- 343
- References
- 0
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis. https://app.cochat.ai/papers/10.1161/01.cir.92.5.1148
- The paper
- Tachibana, K., & Tachibana, S. (1995). Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis. Circulation. https://doi.org/10.1161/01.cir.92.5.1148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.