Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record.

Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis

Tachibana, Katsuro, Tachibana, Shunro·1995·Circulation

Abstract

Background Recent findings suggest that acoustic cavitation is responsible for acceleration of thrombolysis by ultrasound (US) energy. It is known that albumin microbubbles lower the threshold of acoustic cavitation production. Methods and Results The present study was designed to determine whether the presence of albumin microbubbles used for echo-contrast material (Albunex) can further accelerate fibrinolysis by US. Artificial thrombus was produced by Chandler’s loop method with blood extracted from a healthy subject. Urokinase (UK, 1200 IU/mL) was added to the artificial thrombi placed in test tubes. Each thrombus was exposed to US (170 kHz) at a distance of 1.2 cm for a total of 60 seconds at an intensity of 0.5 W/cm 2 at intervals of 2 seconds on and 4 seconds off. Echo-contrast material (0.6×10 6 microspheres per mL) or 5% albumin (for control) was circulated near the thrombus at a rate of 1 mL/min during the US exposure. Fibrinolysis was later determined by percentage of weight loss of thrombus after 60 minutes of incubation (n=15). Fibrinolysis with UK alone was 26.6±4.8%. Fibrinolysis with UK+US treatment was 33.3±5.8%. Further increase of fibrinolysis to 51.3±7.7% occurred in the presence of Albunex (UK+US+Albunex). Statistical differences were obtained between all these groups (ANOVA). Conclusions The presence of the echo-contrast agent induced further acceleration of thrombolysis by US energy. It is suggested that this diagnostic echo-contrast material can be used as an alternative therapeutic US drug enhancer for thrombolysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.5.1148

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 343

Metadata

Authors
Tachibana, K., & Tachibana, S.
Venue
Circulation
Published
1995-09
Volume
92
Issue
5
Pages
1148-1150
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2126485399
Cited by
343
References
0
FWCI
5.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis. https://app.cochat.ai/papers/10.1161/01.cir.92.5.1148
The paper
Tachibana, K., & Tachibana, S. (1995). Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis. Circulation. https://doi.org/10.1161/01.cir.92.5.1148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.