Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 377

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Alterations in Intracellular Calcium Handling Associated With the Inverse Force-Frequency Relation in Human Dilated Cardiomyopathy

Pieske, Burkert, Kretschmann, Bodo, Meyer, Markus, Holubarsch, Christian, Weirich, Jörg, Posival, Herbert, Minami, Kazatomo, Just, Hanjörg, Hasenfuss, Gerd·1995·Circulation

Abstract

Background The present study was performed to test the hypothesis that the altered force-frequency relation in human failing dilated cardiomyopathy may be attributed to alterations in intracellular calcium handling. Methods and Results The force-frequency relation was investigated in isometrically contracting ventricular muscle strip preparations from 5 nonfailing human hearts and 7 hearts with end-stage failing dilated cardiomyopathy. Intracellular calcium cycling was measured simultaneously by use of the bioluminescent photoprotein aequorin. Stimulation frequency was increased stepwise from 15 to 180 beats per minute (37°C). In nonfailing myocardium, twitch tension and aequorin light emission rose with increasing rates of stimulation. Maximum average twitch tension was reached at 150 min−1 and was increased to 212±34% (P<.05) of the value at 15 min−1. Aequorin light emission was lowest at 15 min−1 and was maximally increased at 180 min−1 to 218±39% (P<.01). In the failing myocardium, average isometric tension was maximum at 60 min−1(106±7% of the basal value at 15 min−1,P=NS) and then decreased continuously to 62±9% of the basal value at 180 min−1(P<.002). In the failing myocardium, aequorin light emission was highest at 15 min−1. At 180 min−1, it was decreased to 71±7% of the basal value (P<.01). Including both failing and nonfailing myocardium, there was a close correlation between the frequencies at which aequorin light emission and isometric tension were maximum (r=.92; n=19;P<.001). Action potential duration decreased similarly with increasing stimulation frequencies in nonfailing and end-stage failing myocardium. Sarcoplasmic reticulum 45 Ca 2+uptake, measured in homogenates from the same hearts, was significantly reduced in failing myocardium (3.60±0.51 versus 1.94±0.18 (nmol/L) · min−1· mg protein−1,P<.005). Conclusions These data indicate that the altered force-frequency relation of the failing human myocardium results from disturbed excitation-contraction coupling with decreased calcium cycling at higher rates of stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.5.1169

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 377

Metadata

Authors
Pieske, B., Kretschmann, B., Meyer, M., Holubarsch, C., Weirich, J., Posival, H., Minami, K., Just, H., & Hasenfuss, G.
Venue
Circulation
Published
1995-09
Volume
92
Issue
5
Pages
1169-1178
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1972370207
Cited by
377
References
37
FWCI
20.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Alterations in Intracellular Calcium Handling Associated With the Inverse Force-Frequency Relation in Human Dilated Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.92.5.1169
The paper
Pieske, B., Kretschmann, B., Meyer, M., Holubarsch, C., Weirich, J., Posival, H., Minami, K., Just, H., & Hasenfuss, G. (1995). Alterations in Intracellular Calcium Handling Associated With the Inverse Force-Frequency Relation in Human Dilated Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.92.5.1169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.