Cited by 443Cardiovascular Function and Risk FactorsHemodynamic Monitoring and TherapyCardiac pacing and defibrillation studies

Validation of Myocardial Acceleration During Isovolumic Contraction as a Novel Noninvasive Index of Right Ventricular Contractility: Comparison With Ventricular Pressure-Volume Relations in an Animal Model

Vogel, Michael, Schmidt, Michael R., Kristiansen, Steen B., Cheung, Michael, White, Paul A., Sorensen, Keld, Redington, Andrew N.·2002·Circulation

Abstract

Background— We have demonstrated that myocardial acceleration during isovolumic contraction (IVA) is a sensitive index of left ventricular contractile function. In this study, we assessed the utility of IVA to measure right ventricular (RV) contractile function. Methods and Results— We examined 8 pigs by using tissue Doppler imaging of the RV free wall and simultaneous measurements of intraventricular pressure, volume, maximal elastance (e max ), preload recruitable stroke work, and dP/dt max by conductance catheterization. Animals were paced in the right atrium at a rate of 130 beats per minute (bpm). IVA was compared with elastance during contractility modulation by esmolol and dobutamine and during preload reduction and afterload increase by transient balloon occlusion of the inferior vena cava and pulmonary artery, respectively. Data were also obtained during incremental atrial pacing from 110 to 210 bpm. Esmolol led to a decrease in IVA and dP/dt max . During dobutamine infusion, IVA, dP/dt max , preload recruitable stroke work, and e max all increased significantly. During preload reduction and afterload increase, IVA remained constant up to a reduction of RV volume by 54% and an RV systolic pressure increase of 58%. Pacing up to a rate of 190 bpm led to a stepwise increase in IVA and dP/dt max , with a subsequent fall at a pacing rate of 210 bpm. Conclusions— IVA is a measurement of RV contractile function that is unaffected by preload and afterload changes in a physiological range and is able to measure the force-frequency relation. This novel index may be ideally suited to the assessment of acute changes of RV function in clinical studies.

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000013773.67850.ba

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Vogel, M., Schmidt, M. R., Kristiansen, S. B., Cheung, M., White, P. A., Sorensen, K., & Redington, A. N.
Affiliations
  • Great Ormond Street Hospital (GB)
  • From the Cardiothoracic Unit (M.V., M.C., P.A.W., A.N.R.), Great Ormond Street Hospital for Children, NHS Trust, London, UK, and the Departments of Experimental Research (M.R.S., S.B.K.) and Cardiology (K.S.), Skejby Hospital, Aarhus, Denmark.
Venue
Circulation
Published
2002-04-09
Volume
105
Issue
14
Pages
1693-1699
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2011943289
Cited by
443
References
31
Citations by year
2026: 2 · 2025: 1 · 2024: 5 · 2023: 2 · 2022: 3 · 2021: 8 · 2020: 5 · 2019: 4 · 2018: 13 · 2017: 18 · 2016: 16 · 2015: 28 · 2014: 52 · 2013: 31 · 2012: 25
FWCI
13.09
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
isovolumic contraction, right ventricular contractility, right ventricular function, tissue Doppler imaging, preload recruitable stroke work, dP/dtmax, force-frequency relationship, esmolol, dobutamine, preload reduction, noninvasive cardiac function assessment
MeSH terms
Adrenergic beta-Agonists, Adrenergic beta-Antagonists, Animals, Blood Pressure, Cardiac Pacing, Artificial, Cardiac Volume, Cardiotonic Agents, Echocardiography, Electrocardiography, Cardiac Catheterization, Heart Rate, Heart Ventricles, Myocardial Contraction, Predictive Value of Tests, Swine, Observer Variation, Ventricular Function, Ventricular Function, Right, Electrophysiologic Techniques, Cardiac, Models, Animal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review