Paracrine Coronary Endothelial Control of Left Ventricular Function in Humans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background Similar to endothelial modulation of vascular tone, myocardial contraction may be modulated by cardioactive agents released from the coronary endothelium. To investigate such modulation in humans, we performed invasive assessment of left ventricular (LV) function before, during, and after bicoronary infusion of substance P, which releases nitric oxide from the endothelium. Methods and Results Eight healthy subjects were investigated during diagnostic coronary angiography and eight transplant recipients during annual catheterization. Tip-micromanometer LV pressure was recorded before, during, and after bicoronary (n=16) and right atrial (n=14) infusion of substance P (20 pmol/min). LV angiograms (n=11) were obtained before and at the end of the substance P infusion. At the end of the intracoronary substance P infusion, we observed (1) a fall in LV peak systolic pressure from 147±16 to 139±15 mm Hg (P<.01) in healthy subjects and from 147±25 to 141±22 mm Hg (P<.05) in transplant recipients; (2) a downward and rightward shift of the average LV end-systolic pressure-volume point consistent with depressed systolic performance; and (3) a rise in LV end-diastolic volume at comparable end-diastolic pressure, consistent with increased end-diastolic distensibility. Five minutes after the substance P infusion, LV peak systolic pressure was higher than at baseline in healthy subjects (154±18 mm Hg;P<.05). Right atrial infusion of substance P did not reproduce these changes. Conclusions Bicoronary infusion of substance P modulates LV function in humans, probably through paracrine myocardial action of cardioactive agents released from the coronary endothelium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stark, R. P., McGinn, A. L., & Wilson, R. F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106203242507 · Cited by 222
Cited by
Chronic Heart Failure in the United States: A Manifestation of Coronary Artery Disease
Gheorghiade, M., & Bonow, R. O. (1998) · Circulation · doi:10.1161/01.cir.97.3.282 · Cited by 787
Nitric oxide signalling in cardiovascular health and disease
Farah, C., Michel, L. Y. M., & Balligand, J.-L. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.224 · Cited by 779
Nitric Oxide and Cardiac Function
Kelly, R. A., Balligand, J.-L., & Smith, T. W. (1996) · Circulation Research · doi:10.1161/01.res.79.3.363 · Cited by 711
Brutsaert, D. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00017.2002 · Cited by 697
Endothelial Dysfunction: Does It Matter? Is It Reversible?
Celermajer, D. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00189-7 · Cited by 681
Metadata
- Authors
- Paulus, W. J., Vantrimpont, P. J., & Shah, A. M.
- Venue
- Circulation
- Published
- 1995-10-15
- Volume
- 92
- Issue
- 8
- Pages
- 2119-2126
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2032093326
- Cited by
- 173
- References
- 1
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.