The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Myocardial Perfusion Patterns Related to Thrombolysis in Myocardial Infarction Perfusion Grades After Coronary Angioplasty in Patients With Acute Anterior Wall Myocardial Infarction
Abstract
Background Epicardial coronary flow is occasionally reduced even after coronary intervention despite the absence of vessel obstruction in patients with acute myocardial infarction. Our aim was to clarify the cause and outcomes of radiocontrast slow filling in patients with reperfused acute anterior myocardial infarction by assessing microvascular damage with the use of myocardial contrast echocardiography (MCE) and functional outcomes. Methods and Results We carefully reviewed the cineangiograms of 86 patients who achieved coronary revascularization within 12 hours of the onset and underwent MCE before and soon after recanalization with the intracoronary injection of sonicated microbubbles. Antegrade coronary flow after recanalization was graded by two observers based on Thrombolysis in Myocardial Infarction (TIMI) trial flow grades. Left ventricular ejection fraction was measured on the day of infarction and 1 month later. TIMI grade 2 was observed in 18 patients (21%), and the other 68 patients manifested TIMI grade 3 after recanalization. All patients with TIMI 2 showed substantial MCE no reflow, whereas only 11 patients (16%) with TIMI 3 showed MCE no reflow. Functional improvement was worse in patients with TIMI 2 than in those with TIMI 3 (TIMI 2, 38±8% versus 40±8%, P =NS [acute versus late]; TIMI 3, 44±13% versus 55±13%, P <.001). Among patients with TIMI 3, significant functional improvement was observed only in patients with MCE reflow (MCE reflow, 46±13% versus 57±12%, P <.001; MCE no reflow, 35±11% versus 45±12%, P =NS). Conclusions Despite no obstructive lesion of the vessel, TIMI 2 is caused by advanced microvascular damage and is a highly specific, although not sensitive, predictor of poor functional outcomes in patients with acute myocardial infarction. TIMI 3 does not necessarily indicate myocardial salvage, and detection of MCE no reflow in these patients is particularly useful for the prediction of functional outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chesebro, J. H., Knatterud, G., Roberts, R., Borer, J., Cohen, L. S., Dalen, J., Dodge, H. T., Francis, C. K., Hillis, D., & Ludbrook, P. (1987) · Circulation · doi:10.1161/01.cir.76.1.142 · Cited by 2,244
The “no-reflow” phenomenon after temporary coronary occlusion in the dog
Kloner, R. A., Ganote, C. E., & Jennings, R. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107898 · Cited by 1,842
Ito, H., Tomooka, T., Sakai, N., Yu, H., Higashino, Y., Fujii, K., Masuyama, T., Kitabatake, A., & Minamino, T. (1992) · Circulation · doi:10.1161/01.cir.85.5.1699 · Cited by 1,054
Self-citationIto, H., Maruyama, A., Iwakura, K., Takiuchi, S., Masuyama, T., Hori, M., Higashino, Y., Fujii, K., & Minamino, T. (1996) · Circulation · doi:10.1161/01.cir.93.2.223 · Cited by 1,021
Self-citationSheehan, F. H., Bolson, E. L., Dodge, H. T., Mathey, D. G., Schofer, J. J., & Woo, H. W. (1986) · Circulation · doi:10.1161/01.cir.74.2.293 · Cited by 633
Incidence and treatment of 'no-reflow' after percutaneous coronary intervention.
Piana, R. N., Paik, G. Y., Moscucci, M., Cohen, D. J., Gibson, C. M., Kugelmass, A. D., Carrozza, J. P., Kuntz, R. E., & Baim, D. S. (1994) · Circulation · doi:10.1161/01.cir.89.6.2514 · Cited by 521
Kloner, R. A., Rude, R. E., Carlson, N., Maroko, P. R., DeBoer, L. W., & Braunwald, E. (1980) · Circulation · doi:10.1161/01.cir.62.5.945 · Cited by 484
Ambrosio, G., Weisman, H. F., Mannisi, J. A., & Becker, L. C. (1989) · Circulation · doi:10.1161/01.cir.80.6.1846 · Cited by 468
Ragosta, M., Camarano, G., Kaul, S., Powers, E. R., Sarembock, I. J., & Gimple, L. W. (1994) · Circulation · doi:10.1161/01.cir.89.6.2562 · Cited by 368
Kloner, R. A., Sg, E., Lange, R., & D, E. B. M. (1983) · PubMed · Cited by 362
Karagounis, L., Sorensen, S. G., Menlove, R. L., Moreno, F., & Anderson, J. L. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90043-m · Cited by 238
Morishima, I., Sone, T., Mokuno, S., Taga, S., Shimauchi, A., Oki, Y., Kondo, J., Tsuboi, H., & Sassa, H. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90434-4 · Cited by 184
Villanueva, F. S., Glasheen, W. P., Sklenar, J., & Kaul, S. (1993) · Circulation · doi:10.1161/01.cir.88.6.2596 · Cited by 173
INTENSE MICROVASCULAR CONSTRICTION AFTER ANGIOPLASTY OF ACUTE THROMBOTIC CORONARY ARTERIAL LESIONS
Wilson, R., Lesser, J., Laxson, D., & White, C. (1989) · The Lancet · doi:10.1016/s0140-6736(89)92271-x · Cited by 168
Ito, H., Iwakura, K., Oh, H., Masuyama, T., Hori, M., Higashino, Y., Fujii, K., & Minamino, T. (1995) · Circulation · doi:10.1161/01.cir.91.3.656 · Cited by 147
Self-citationJeremy, R., Links, J. M., & Becker, L. C. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90362-s · Cited by 131
Feld, H., Lichstein, E., Schachter, J., & Shani, J. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90520-6 · Cited by 59
Pomerantz, R. M., Kuntz, R. E., Diver, D. J., Safian, R. D., & Baim, D. S. (1991) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810240414 · Cited by 56
Demonstration of the “no-reflow” phenomenon by digital coronary arteriography
Bates, E., Krell, M. J., Dean, E. N., O’Neill, W. W., & Vogel, R. A. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90976-8 · Cited by 53
Nicklas, J. M., Diltz, E. A., O’Neill, W. W., Bourdillon, P. D. V., Walton, J. A., & Pitt, B. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80009-8 · Cited by 34
Cited by
Wu, K. C., Zerhouni, E. A., Judd, R. M., Lugo-Olivieri, C. H., Barouch, L. A., Schulman, S. P., Blumenthal, R. S., & Lima, J. A. C. (1998) · Circulation · doi:10.1161/01.cir.97.8.765 · Cited by 1,357
van ‘t Hof, A. W. J., Liem, A., Suryapranata, H., Hoorntje, J. C. A., de Boer, M.-J., & Zijlstra, F. (1998) · Circulation · doi:10.1161/01.cir.97.23.2302 · Cited by 1,307
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Rezkalla, S. H., & Kloner, R. A. (2002) · Circulation · doi:10.1161/hc0502.102867 · Cited by 621
Morishima, I., Sone, T., Okumura, K., Tsuboi, H., Kondo, J., Mukawa, H., Matsui, H., Toki, Y., Ito, T., & Hayakawa, T. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00865-2 · Cited by 577
Metadata
- Authors
- Ito, H., Okamura, A., Iwakura, K., Masuyama, T., Hori, M., Takiuchi, S., Negoro, S., Nakatsuchi, Y., Taniyama, Y., Higashino, Y., Fujii, K., & Minamino, T.
- Venue
- Circulation
- Published
- 1996-06
- Volume
- 93
- Issue
- 11
- Pages
- 1993-1999
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2057438016
- Cited by
- 430
- References
- 20
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.