Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

Importance of Pressure Recovery for the Assessment of Aortic Stenosis by Doppler Ultrasound: Role of Aortic Size, Aortic Valve Area, and Direction of the Stenotic Jet In Vitro

Niederberger, Julia, Schima, Heinrich, Maurer, Gerald, Baumgartner, Helmut·1996·Circulation

Abstract

Background Pressure recovery has been shown to occur distal to aortic stenoses in experimental and clinical studies. However, its clinical relevance in this setting has not yet been evaluated. Methods and Results To address the hypothesis that pressure recovery can cause significant differences between Doppler and catheter gradients in aortic stenosis and to examine the effects of aortic size, aortic valve area, and direction of the stenotic jet on these differences, stenoses with valve areas from 0.5 to 1.25 cm 2 and aortic diameters from 1.8 to 5.0 cm were studied in a pulsatile flow model. Jets entered the aorta centrally or eccentrically with angles of 15°, 30°, or 45°. Overall, good correlation was found between Doppler and catheter gradients. However, when the various combinations of orifices and aortas were analyzed separately, slopes varied from 1.0 to 1.86, and the Doppler-catheter gradient differences ranged from −2 (small valve area with a large aorta) to 66 mm Hg (80% overestimation by Doppler echocardiography) when the stenosis was moderate and the aorta was small. Mild eccentricity of the jet did not significantly alter the results. However, overestimation by Doppler decreased with increasing jet eccentricity. Finally, differences between Doppler and catheter gradients could be predicted by estimating pressure recovery from Doppler measurements. Conclusions Significant pressure recovery can occur in aortic stenosis and can cause differences between Doppler and catheter gradients. These differences may reach clinical relevance, particularly when the stenosis is moderate and the aorta is small and can be predicted from Doppler measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.8.1934

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Niederberger, J., Schima, H., Maurer, G., & Baumgartner, H.
Venue
Circulation
Published
1996-10-15
Volume
94
Issue
8
Pages
1934-1940
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2072419771
Cited by
176
References
0
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Importance of Pressure Recovery for the Assessment of Aortic Stenosis by Doppler Ultrasound: Role of Aortic Size, Aortic Valve Area, and Direction of the Stenotic Jet In Vitro. https://app.cochat.ai/papers/10.1161/01.cir.94.8.1934
The paper
Niederberger, J., Schima, H., Maurer, G., & Baumgartner, H. (1996). Importance of Pressure Recovery for the Assessment of Aortic Stenosis by Doppler Ultrasound: Role of Aortic Size, Aortic Valve Area, and Direction of the Stenotic Jet In Vitro. Circulation. https://doi.org/10.1161/01.cir.94.8.1934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.