Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of Left Ventricular Filling Pressures by Doppler in the Presence of Atrial Fibrillation

Nagueh, Sherif F., Kopelen, Helen A., Quin˜ones, Miguel A.·1996·Circulation

Abstract

Background Although Doppler echocardiography can be used to estimate left ventricular filling pressures (LVFPs) in patients in sinus rhythm, its utility in atrial fibrillation is unknown. Methods and Results An initial training population of 30 patients (17 men, 13 women; mean age, 69±9 years; range, 48 to 87 years) was studied. Measurements of LVFP were obtained simultaneously with pulsed Doppler recordings of mitral and pulmonary venous flow velocities and color M-mode recording of the flow propagation velocity of the mitral inflow. Measurements were averaged over 10 cardiac cycles. In addition, left atrial volume was derived from the apical four-chamber view. Significant relations were observed between LVFP and several parameters derived from the transmitral and pulmonary venous velocity and left atrial volume. The best relations were observed with the peak acceleration (PkAcc) of the mitral velocity ( r =.84), isovolumic relaxation time (IVRT) ( r =−.76), mean early (E) velocity ( r =.6), and the ratio of peak E velocity to color M-mode flow propagation velocity ( r =.65). The best model obtained by multilinear regression analysis ( r =.88) included PkAcc and IVRT. The equation \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \(LVFP{=}22{+}0.005(PkAcc){-}0.183(IVRT)\) \end{document} was tested in 30 additional patients (12 women and 18 men; mean age, 65±10.6 years; range, 43 to 87 years) with similar results ( r =.87). When all 60 patients were combined, the mean±1SD difference between predicted and observed pressure was −0.88±3.6 mm Hg. Conclusions LVFPs can be estimated with Doppler echocardiography in patients with atrial fibrillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.9.2138

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 296

Metadata

Authors
Nagueh, S. F., Kopelen, H. A., & Quin˜ones, M. A.
Venue
Circulation
Published
1996-11
Volume
94
Issue
9
Pages
2138-2145
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2081183027
Cited by
296
References
1
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Left Ventricular Filling Pressures by Doppler in the Presence of Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/01.cir.94.9.2138
The paper
Nagueh, S. F., Kopelen, H. A., & Quin˜ones, M. A. (1996). Assessment of Left Ventricular Filling Pressures by Doppler in the Presence of Atrial Fibrillation. Circulation. https://doi.org/10.1161/01.cir.94.9.2138

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.