The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Transvenous Closure of Secundum Atrial Septal Defects: Preliminary Results With a New Self-Expanding Nitinol Prosthesis in a Swine Model
Abstract
Background Our purpose was to evaluate a new prosthesis for percutaneous closure of secundum atrial septal defects (ASDs). Methods and Results Percutaneous closure of surgically created fossa ovalis ASD was attempted in 15 minipigs. The mean balloon-stretched ASD diameter was 12.3±2.3 mm (range, 10 to 16 mm). The self-expanding prosthesis was braided from 0.005-in Nitinol wires in the shape of two flat buttons with a short connecting waist with a diameter corresponding to that of the defect to be closed. Polyester filling was added to enhance thrombogenicity. Pulmonary arteriography with levo-phase was obtained before placement; immediately after placement; and at 1-week, 1-month, and 3-month follow-ups. Four animals were killed at 1 week, 1 month, and 3 months for histopathological correlation. Three deaths resulted from ventricular fibrillation (one during anesthesia and two during the placement procedure). Successful placement of the prosthesis was achieved in the remaining 12 animals. Overall immediate ASD closure on angiography occurred in 7 of 12 animals (all polyester-filled prostheses). Absent or trace shunt by angiography was present in 11 of 12 devices at 1 week, with the remaining one demonstrating a small shunt. All septal defects were completely closed at 1 month with the exception of one case in which delayed partial dislodgment of an undersized prosthesis into the right atrium had developed. Closure rate at 3 months was 100%. Neoendothelialization and fibrous incorporation of the prosthesis were completed within 1 to 3 months. Conclusions Effective and permanent occlusion of secundum ASDs is feasible with a device that offers the advantages of easy placement, self-centering, and repositionability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murphy, J. G., Gersh, B. J., McGoon, M. D., Mair, D. D., Porter, C.-B. J., Ilstrup, D. M., McGoon, D. C., Puga, F. J., Kirklin, J. W., & Danielson, G. K. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012133232401 · Cited by 776
Cited by
Du, Z.-D., Hijazi, Z. M., Kleinman, C. S., Silverman, N. H., & Larntz, K. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01862-4 · Cited by 961
Krumsdorf, U., Ostermayer, S., Billinger, K., Trepels, T., Zadan, E., Horvath, K., & Sievert, H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.030 · Cited by 596
Chan, K. C., Godman, M. J., Walsh, K., Wilson, N., Redington, A., & Gibbs, J. L. (1999) · Heart · doi:10.1136/hrt.82.3.300 · Cited by 307
Fischer, G., Stieh, J., Uebing, A., Hoffmann, U., Morf, G., & Kramer, H. H. (2003) · Heart · doi:10.1136/heart.89.2.199 · Cited by 288
Masura, J., Gavora, P., & Podnar, T. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.066 · Cited by 268
Metadata
- Authors
- Sharafuddin, M. J. A., Gu, X., Titus, J. L., Urness, M., Cervera-Ceballos, J. J., & Amplatz, K.
- Venue
- Circulation
- Published
- 1997-04-15
- Volume
- 95
- Issue
- 8
- Pages
- 2162-2168
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2043288177
- Cited by
- 244
- References
- 1
- FWCI
- 19.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transvenous Closure of Secundum Atrial Septal Defects: Preliminary Results With a New Self-Expanding Nitinol Prosthesis in a Swine Model. https://app.cochat.ai/papers/10.1161/01.cir.95.8.2162
- The paper
- Sharafuddin, M. J. A., Gu, X., Titus, J. L., Urness, M., Cervera-Ceballos, J. J., & Amplatz, K. (1997). Transvenous Closure of Secundum Atrial Septal Defects: Preliminary Results With a New Self-Expanding Nitinol Prosthesis in a Swine Model. Circulation. https://doi.org/10.1161/01.cir.95.8.2162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.