CoChat

Patients With Valvular Heart Disease Presenting With Sustained Ventricular Tachyarrhythmias or Syncope: Results of Programmed Ventricular Stimulation and Long-term Follow-up

Martínez-Rubio, Antoni, Schwammenthal, Yvonne, Schwammenthal, Ehud, Block, Michael, Reinhardt, Lutz, Garcia-Alberola, Arcadi, Sierra, Gilberto, Shenasa, Mohammad, Haverkamp, Wilhelm, Scheld, Hans H., Breithardt, Günter, Borggrefe, Martin · 1997 · Circulation
Cited by 58

The DOI matches its Crossref record.

Abstract

Background Programmed ventricular stimulation is commonly used to guide therapy in post–myocardial infarction patients with sustained monomorphic ventricular tachycardia (VT) or ventricular fibrillation (VF). In patients with valvular heart disease presenting with spontaneous VT, VF, or syncope, the usefulness of this technique is still unclear. The aim of the study was to analyze whether programmed ventricular stimulation was helpful in guiding therapy and determining prognosis in 97 patients with valvular heart disease presenting with VT (60%), VF (18%), or syncope (22%). Methods and Results Patients were classified as having either predominant ventricular pressure or volume overload or no significant pressure or volume overload. Overall, sustained VT or VF was inducible in 38 (39%) and 19 (20%) patients, respectively. Forty-six (47%) patients were discharged on antiarrhythmic drugs, 29 (30%) received an implantable cardioverter-defibrillator, and 22 (23%) remained without therapy. With serial drug testing, inducibility was completely or partially suppressed in 18 (19%) and 9 (9%) patients, respectively. During a mean follow-up of 51 months (n=97), 17 patients (18%) died (sudden death, n=7; heart failure, n=4; noncardiac causes, n=6). One-, 2- and 3-year event-free survival for sudden death, sustained VT, or VF was 77%, 68%, and 61%, respectively. Only inducibility of VT during baseline study ( P <.0003) and left ventricular volume overload ( P <.008) were significant predictors of arrhythmic events. Recurrence of arrhythmic events occurred in 56% and 56% of patients with complete or partial suppression of inducibility during serial drug testing as well as in 10 of 19 (53%) patients without a change in inducibility. Conclusions Although programmed ventricular stimulation seems to predict adverse outcome, serial drug testing is unreliable in guiding therapy. The type of workload imposed on the ventricles influences outcome, being worse in patients with left ventricular volume overload. Therefore, implantation of a cardioverter-defibrillator should be considered early for the management of these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.2.500

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Martínez-Rubio, A., Schwammenthal, Y., Schwammenthal, E., Block, M., Reinhardt, L., Garcia-Alberola, A., Sierra, G., Shenasa, M., Haverkamp, W., Scheld, H. H., Breithardt, G., & Borggrefe, M.
Venue
Circulation
Published
1997-07-15
Volume
96
Issue
2
Pages
500-508
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2162984348
Cited by
58
References
0
FWCI
1.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patients With Valvular Heart Disease Presenting With Sustained Ventricular Tachyarrhythmias or Syncope: Results of Programmed Ventricular Stimulation and Long-term Follow-up. https://app.cochat.ai/papers/10.1161/01.cir.96.2.500
The paper
Martínez-Rubio, A., Schwammenthal, Y., Schwammenthal, E., Block, M., Reinhardt, L., Garcia-Alberola, A., Sierra, G., Shenasa, M., Haverkamp, W., Scheld, H. H., Breithardt, G., & Borggrefe, M. (1997). Patients With Valvular Heart Disease Presenting With Sustained Ventricular Tachyarrhythmias or Syncope: Results of Programmed Ventricular Stimulation and Long-term Follow-up. Circulation. https://doi.org/10.1161/01.cir.96.2.500

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.