The DOI matches its Crossref record.
Long-term Angiographic and Clinical Outcome After Percutaneous Transluminal Coronary Angioplasty and Intracoronary Radiation Therapy in Humans
Abstract
Background Ionizing radiation has been shown to reduce neointimal formation after balloon angioplasty in experimental models of restenosis. This study was designed to evaluate the feasibility, safety, and effectiveness of intracoronary radiation therapy (ICRT) after percutaneous transluminal coronary angioplasty (PTCA) for preventing restenosis in human coronary arteries. Methods and Results Twenty-one patients (22 arteries) with unstable angina underwent standard balloon angioplasty. ICRT was performed with the use of an 192 Ir source wire that was hand delivered to the angioplasty site. Angiographic follow-up was performed at 24 hours, between 30 and 60 days, and at 6 months. Angioplasty was successful in 19 of 22 lesions, and insertion of the radioactive source wire was successful at all treated sites. Angiographic study at 24 hours demonstrated early late loss of the luminal diameter from 1.92±0.55 to 1.40±0.27 mm. Between 30 and 60 days, repeat angiography demonstrated total occlusion in 2 arteries, a new pseudoaneurysm in 1 artery, and significant dilatation at the treatment site in 2 additional vessels. At ≥6 months’ follow-up, all remaining arteries (n=20) maintained patent, with a mean lumen diameter of 1.65±0.8 mm. The calculated late lumen loss was 0.27±0.56 mm, and the late loss index was 0.19. Clinical events at 1 year included myocardial infarction in 1 patient, repeat angioplasty to the treated site in 3 patients, and persistent angina in 7 patients. Conclusions These preliminary results demonstrate that ICRT after coronary intervention is feasible and is associated with an acceptable degree of complications and lower rates of angiographic restenosis indexes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Verin, V., Popowski, Y., de Bruyne, B., Baumgart, D., Sauerwein, W., Lins, M., Kovacs, G., Thomas, M., Calman, F., Disco, C., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200101253440401 · Cited by 263
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Metadata
- Authors
- Condado, J. A., Waksman, R., Gurdiel, O., Espinosa, R., Gonzalez, J., Burger, B., Villoria, G., Acquatella, H., Crocker, I. R., Seung, K. B., & Liprie, S. F.
- Venue
- Circulation
- Published
- 1997-08-05
- Volume
- 96
- Issue
- 3
- Pages
- 727-732
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2002935714
- Cited by
- 348
- References
- 0
- FWCI
- 44.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term Angiographic and Clinical Outcome After Percutaneous Transluminal Coronary Angioplasty and Intracoronary Radiation Therapy in Humans. https://app.cochat.ai/papers/10.1161/01.cir.96.3.727
- The paper
- Condado, J. A., Waksman, R., Gurdiel, O., Espinosa, R., Gonzalez, J., Burger, B., Villoria, G., Acquatella, H., Crocker, I. R., Seung, K. B., & Liprie, S. F. (1997). Long-term Angiographic and Clinical Outcome After Percutaneous Transluminal Coronary Angioplasty and Intracoronary Radiation Therapy in Humans. Circulation. https://doi.org/10.1161/01.cir.96.3.727
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.