Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

The Road to Bioabsorbable Stents: Reaching Clinical Reality?

Erne, Paul, Schier, Matthias, Resink, Therese J. · 2006 · CardioVascular and Interventional Radiology

Abstract

This article provides an overview of the evolution of revascularization devices since Grüntzig's initial introduction of balloon angioplasty in 1977. In-stent restenosis (ISR) is the major shortcoming of conventional (permanent-implant) stent therapy; even with the innovation and promising benefits of drug-eluting stents, management of ISR is very difficult. ISR is mainly caused by the interaction between the blood and the stent surface and a permanent mechanical irritation of the vascular tissue. Thus stenting technology has moved toward the development of temporary implants composed of biocompatible materials which mechanically support the vessel during the period of high risk for recoil and then completely biodegrade in the long term. Preclinical and first clinical experiences with bioabsorbable magnesium stents are discussed.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00270-004-0341-9

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 59 references

Research works printed but not linked: 2

  1. Duda SH, Pusich B, Richter G, et al. (2002) Sirolimus-eluting stents for the treatment of obstructive superficial femoral arte\rventions in iliac and infrainguinal occlusive artery disease. J Interv Cardiol 17:427–435
  2. Sawyer P, Brattain W, Boddy P (1965) Electrochemical criteria in the choice of materials used in vascular prosthesis. In: Sawyer P (ed) Biophysical mechanism in vascular hemostasis and intravascular thrombosis. Appleton-Century-Crofts, New York, pp 337–348

Cited by

See all 276

Metadata

Authors
Erne, P., Schier, M., & Resink, T. J.
Affiliations
Biotronik (Germany) (DE)
Venue
CardioVascular and Interventional Radiology
Published
2005-09-29
Volume
29
Issue
1
Pages
11-16
ISSN
  • 0174-1551 (ISSN-L)
  • 1432-086X
OpenAlex
W1985328726
Cited by
249
References
59
Citations by year
2026: 5 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 12 · 2021: 12 · 2020: 12 · 2019: 12 · 2018: 10 · 2017: 19 · 2016: 13 · 2015: 19 · 2014: 20 · 2013: 19 · 2012: 14
FWCI
5.71
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • CardioVascular and Interventional Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
  • Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
biodegradable stents, in-stent restenosis, drug-eluting stents, magnesium stents, coronary revascularization, balloon angioplasty, biodegradable implants, biomaterials, stent recoil, vascular injury
MeSH terms
Coronary Artery Disease, Humans, Iron, Magnesium, Polymers, Stents, Drug Delivery Systems, Absorbable Implants, Coronary Restenosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Road to Bioabsorbable Stents: Reaching Clinical Reality? https://app.cochat.ai/papers/10.1007/s00270-004-0341-9
The paper
Erne, P., Schier, M., & Resink, T. J. (2006). The Road to Bioabsorbable Stents: Reaching Clinical Reality? CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-004-0341-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.