Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Heart Failure and Echocardiographic Changes During Long-term Follow-up of Patients With Sick Sinus Syndrome Randomized to Single-Chamber Atrial or Ventricular Pacing

Nielsen, Jens Cosedis, Andersen, Henning Rud, Thomsen, Poul Erik Bloch, Thuesen, Leif, Mortensen, Peter Thomas, Vesterlund, Thomas, Pedersen, Anders Kirstein·1998·Circulation

Abstract

Background —In patients with sick sinus syndrome, choice of pacing mode has been implicated in the development of congestive heart failure. Methods and Results —A total of 225 consecutive patients with sick sinus syndrome and intact atrioventricular conduction were randomized to either single-chamber atrial pacing (n=110) or single-chamber ventricular pacing (n=115). Clinical assessment included New York Heart Association classification, medication, and M-mode echocardiography before pacemaker implantation, after 3 months, and subsequently once every year. At long-term follow-up (mean, 5.5±2.4 years), NYHA class was higher in the ventricular group than in the atrial group (NYHA class I/II/III/IV: 65/44/4/0 versus 84/22/2/1 patients, P =.010). Increase in NYHA class during follow-up was observed in 35 of 113 patients in the ventricular group versus 10 of 109 in the atrial group ( P <.0005). Increase in dose of diuretics from randomization to last follow-up was significantly higher in the ventricular group than in the atrial group (21±49 versus 8±42 mg furosemide/d, P =.033). The left ventricular fractional shortening decreased significantly in the ventricular group (from 0.36±0.12 to 0.31±0.08, P <.0005) but not in the atrial group (from 0.35±0.13 to 0.33±0.09, P =.087). The left atrial diameter increased significantly in both treatment groups (ventricular group: from 34±7 to 41±7 mm, P <.0005; atrial group: from 34±6 to 37±7 mm, P =.002), but the increase was significantly higher in the ventricular group than in the atrial group ( P <.0005). Conclusions —During long-term follow-up, ventricular pacing is associated with a higher incidence of congestive heart failure and consumption of diuretics than atrial pacing. This is accompanied by a decrease in left ventricular fractional shortening and an increased dilatation of the left atrium in the ventricular paced patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.97.10.987

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 229

Metadata

Authors
Nielsen, J. C., Andersen, H. R., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K.
Venue
Circulation
Published
1998-03-17
Volume
97
Issue
10
Pages
987-995
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2102854495
Cited by
229
References
1
FWCI
7.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Failure and Echocardiographic Changes During Long-term Follow-up of Patients With Sick Sinus Syndrome Randomized to Single-Chamber Atrial or Ventricular Pacing. https://app.cochat.ai/papers/10.1161/01.cir.97.10.987
The paper
Nielsen, J. C., Andersen, H. R., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1998). Heart Failure and Echocardiographic Changes During Long-term Follow-up of Patients With Sick Sinus Syndrome Randomized to Single-Chamber Atrial or Ventricular Pacing. Circulation. https://doi.org/10.1161/01.cir.97.10.987

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.