CoChat

Reversal of Abnormal Coronary Vasomotion by Calcium Antagonists in Patients With Hypercholesterolemia

Open access
Kaufmann, Philipp A., Frielingsdorf, Jürgen, Mandinov, Lazar, Seiler, Christian, Hug, Rosy, Hess, Otto M. · 1998 · Circulation
Cited by 30

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background —It has been shown that exercise-induced coronary vasodilation of angiographically normal coronary vessels is reduced in hypercholesterolemic patients. The purpose of this study was to evaluate the effect of calcium channel blockers on coronary vasomotion of angiographically smooth coronary arteries in hypercholesterolemic patients. Methods and Results —A total of 57 patients were included in the present analysis. Vasomotion of angiographically normal coronary arteries was evaluated in 37 control subjects (group 1) without and 20 patients (group 2) with calcium blocker administration before physical exercise. Both groups were subdivided into subgroup A (normal cholesterol values: ≤5.5 mmol/L or 212 mg%) and subgroup B (elevated cholesterol values: >5.5 mmol/L or 212 mg%). Coronary luminal area at rest and during exercise was assessed by biplane quantitative coronary angiography. The normal vessels showed a significant increase in coronary luminal area during exercise in subgroup A (n=13) with normal cholesterol values (31%; P <.05) but not in subgroup B (n=24; 13%; P =NS). In contrast, all patients in group 2 showed similar vasodilation during exercise, namely, 22% ( P <.05) in subgroups A (n=8) and B (n=12) ( P <.05). Independent of the actual cholesterol level, the stenotic lesions showed coronary vasoconstriction during exercise in group 1 but vasodilation in group 2 after pretreatment with calcium antagonists. Conclusions —Coronary vasomotor response to exercise is inversely related to actual serum cholesterol level in angiographically normal vessels. Administration of calcium antagonists normalizes exercise-induced vasodilation and thus eliminates cholesterol-induced abnormal vasomotion, probably by a direct effect on the smooth muscles of the vasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.97.14.1348

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 30

Metadata

Authors
Kaufmann, P. A., Frielingsdorf, J., Mandinov, L., Seiler, C., Hug, R., & Hess, O. M.
Venue
Circulation
Published
1998-04-14
Volume
97
Issue
14
Pages
1348-1354
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1979225573
Cited by
30
References
1
FWCI
5.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.