Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 479

The DOI matches its Crossref record.

Spatiotemporal Periodicity During Atrial Fibrillation in the Isolated Sheep Heart

Skanes, Allan C., Mandapati, Ravi, Berenfeld, Omer, Davidenko, Jorge M., Jalife, José·1998·Circulation

Abstract

Background —The activation patterns that underlie the irregular electrical activity during atrial fibrillation (AF) have traditionally been described as disorganized or random. Recent studies, based predominantly on statistical methods, have provided evidence that AF is spatially organized. The objective of this study was to demonstrate the presence of spatial and temporal periodicity during AF. Methods and Results —We used a combination of high-resolution video imaging, ECG recordings, and spectral analysis to identify sequential wave fronts with temporal periodicity and similar spatial patterns of propagation during 20 episodes of AF in 6 Langendorff-perfused sheep hearts. Spectral analysis of AF demonstrated multiple narrow-band peaks with a single dominant peak in all cases (mean, 9.4±2.6 Hz; cycle length, 112±26 ms). Evidence of spatiotemporal periodicity was found in 12 of 20 optical recordings of the right atrium (RA) and in all (n=19) recordings of the left atrium (LA). The cycle length of spatiotemporal periodic waves correlated with the dominant frequency of their respective optical pseudo-ECGs (LA: R 2 =0.99, slope=0.94 [95% CI, 0.88 to 0.99]; RA: R 2 =0.97, slope=0.92 [95% CI, 0.80 to 1.03]). The dominant frequency of the LA pseudo-ECG alone correlated with the global bipolar atrial EG ( R 2 =0.76, slope=0.75 [95% CI, 0.52 to 0.99]). In specific examples, sources of periodic activity were seen as rotors in the epicardial sheet or as periodic breakthroughs that most likely represented transmural pectinate muscle reentry. However, in the majority of cases, periodic waves were seen to enter the mapping area from the edge of the field of view. Conclusions —Reentry in anatomically or functionally determined circuits forms the basis of spatiotemporal periodic activity during AF. The cycle length of sources in the LA determines the dominant peak in the frequency spectra in this experimental model of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.12.1236

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 479

Metadata

Authors
Skanes, A. C., Mandapati, R., Berenfeld, O., Davidenko, J. M., & Jalife, J.
Venue
Circulation
Published
1998-09-22
Volume
98
Issue
12
Pages
1236-1248
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2060368349
Cited by
479
References
0
FWCI
10.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatiotemporal Periodicity During Atrial Fibrillation in the Isolated Sheep Heart. https://app.cochat.ai/papers/10.1161/01.cir.98.12.1236
The paper
Skanes, A. C., Mandapati, R., Berenfeld, O., Davidenko, J. M., & Jalife, J. (1998). Spatiotemporal Periodicity During Atrial Fibrillation in the Isolated Sheep Heart. Circulation. https://doi.org/10.1161/01.cir.98.12.1236

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.