CoChat

Central Vagotonic Effects of Atropine Modulate Spectral Oscillations of Sympathetic Nerve Activity

Open access
Montano, Nicola, Cogliati, Chiara, Porta, Alberto, Pagani, Massimo, Malliani, Alberto, Narkiewicz, Krzysztof, Abboud, Francois M., Birkett, Clay, Somers, Virend K. · 1998 · Circulation
Cited by 156

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background —Low-dose atropine causes bradycardia either by acting on the sinoatrial node or by its effects on central muscarinic receptors increasing vagal activity. Any central muscarinic effects of high-dose atropine on RR interval are masked by peripheral muscarinic blockade at the sinoatrial node, which causes tachycardia. Effects of central parasympathetic activation on sympathetic activity are not known. Methods and Results —Using power spectral analysis of RR interval, intra-arterial blood pressure, respiration, and muscle sympathetic nerve activity (MSNA), we examined the effects of both low (2 μg/kg IV) and high (15 μg/kg IV) doses of atropine. After low-dose atropine, RR increased by 9±1% ( P <0.0001), the low-frequency (LF) component (in normalized units, NU) of RR variability decreased by −32±8%, and the high-frequency (HF) NU component increased (+74±19%); hence, LF/HF of RR variability fell by 52±10% (all P <0.01). Although overall MSNA did not change, LF NU of MSNA decreased (−15±5%), HF NU of MSNA increased (+31±3%), and LF/HF of MSNA fell (−41±8%) (all P <0.01). After high-dose atropine, LF NU of MSNA decreased (−17±12%), HF NU of MSNA increased (+22±3%), and LF/HF of MSNA fell (−51±21%) (all P <0.02). Conclusions —Increasing central parasympathetic activity with low-dose atropine is associated with an increase in the HF and a decrease in the LF oscillations of both RR interval and MSNA variability. High-dose atropine similarly induces an increase in the HF and a decrease in the LF components of MSNA variability. Thus, central parasympathetic activation is able to modulate the oscillatory characteristics of sympathetic nerve traffic to peripheral blood vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.14.1394

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 156

Metadata

Authors
Montano, N., Cogliati, C., Porta, A., Pagani, M., Malliani, A., Narkiewicz, K., Abboud, F. M., Birkett, C., & Somers, V. K.
Venue
Circulation
Published
1998-10-06
Volume
98
Issue
14
Pages
1394-1399
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2126141386
Cited by
156
References
8
FWCI
6.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.