Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 223

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Noninvasive In Vivo High-Resolution Magnetic Resonance Imaging of Atherosclerotic Lesions in Genetically Engineered Mice

Open access
Fayad, Zahi A., Fallon, John T., Shinnar, Meir, Wehrli, Suzanne, Dansky, Hayes M., Poon, Michael, Badimon, Juan J., Charlton, Sherri A., Fisher, Edward A., Breslow, Jan L., Fuster, Valentin · 1998 · Circulation

Abstract

Background —The pathogenesis of atherosclerosis is currently being investigated in genetically engineered small animals. Methods to follow the time course of the developing pathology and/or the responses to therapy in vivo are limited. Methods and Results —To address this problem, we developed a noninvasive MR microscopy technique to study in vivo atherosclerotic lesions (without a priori knowledge of the lesion location or lesion type) in live apolipoprotein E–knockout (apoE-KO) mice. The spatial resolution was 0.0012 to 0.005 mm 3 . The lumen and wall of the abdominal aorta and iliac arteries were identified on all images in apoE-KO (n=8) and wild-type (n=5) mice on chow diet. Images obtained with MR were compared with corresponding cross-sectional histopathology (n=58). MR accurately determined wall area in comparison to histopathology (slope=1.0, r =0.86). In addition, atherosclerotic lesions were characterized in terms of lesion shape and type. Lesion type was graded by MR according to morphological appearance/severity and by histopathology according to the AHA classification. There was excellent agreement between MR and histopathology in grading of lesion shape and type (slope=0.97, r =0.91 for lesion shape; slope=0.64, r =0.90 for lesion type). Conclusions —The combination of high-resolution MR microscopy and genetically engineered animals is a powerful tool to investigate serially and noninvasively the progression and regression of atherosclerotic lesions in an intact animal model and should greatly enhance basic studies of atherosclerotic disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.15.1541

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 223

Metadata

Authors
Fayad, Z. A., Fallon, J. T., Shinnar, M., Wehrli, S., Dansky, H. M., Poon, M., Badimon, J. J., Charlton, S. A., Fisher, E. A., Breslow, J. L., & Fuster, V.
Venue
Circulation
Published
1998-10-13
Volume
98
Issue
15
Pages
1541-1547
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2171433980
Cited by
223
References
3
FWCI
17.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive In Vivo High-Resolution Magnetic Resonance Imaging of Atherosclerotic Lesions in Genetically Engineered Mice. https://app.cochat.ai/papers/10.1161/01.cir.98.15.1541
The paper
Fayad, Z. A., Fallon, J. T., Shinnar, M., Wehrli, S., Dansky, H. M., Poon, M., Badimon, J. J., Charlton, S. A., Fisher, E. A., Breslow, J. L., & Fuster, V. (1998). Noninvasive In Vivo High-Resolution Magnetic Resonance Imaging of Atherosclerotic Lesions in Genetically Engineered Mice. Circulation. https://doi.org/10.1161/01.cir.98.15.1541

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.