Low Incidence of Myocardial Recovery After Left Ventricular Assist Device Implantation in Patients With Chronic Heart Failure

Mancini, Donna M., Beniaminovitz, Ainat, Levin, Howard, Catanese, Katharine, Flannery, Margaret, DiTullio, Marco, Savin, Sergey, Cordisco, Marie Elena, Rose, Eric, Oz, Mehmet·1998·Circulation

Abstract

Background —Mechanical, histological, and biochemical improvement has been described in patients after left ventricular assist device (LVAD) support. Explantation of the LVADs without heart transplantation has been described in selected patients who received this therapy as a bridge to transplantation. Methods and Results —A retrospective review of patients receiving a mechanical bridge to transplantation at Columbia Presbyterian Hospital after July 21, 1991, was performed to determine the incidence of patients in whom the device was successfully explanted. From August 1, 1996, to February 1, 1998, we prospectively attempted to identify potential explant candidates by the use of exercise testing. During this time, we recruited 39 consecutive patients after insertion of the Thermo Cardiosystems vented electric device to participate in the following study. Approximately 3 months after device implantation, a maximal exercise test with hemodynamic monitoring and respiratory gas analysis was performed with the LVAD in the automated mode. The electric device was interfaced with a pneumatic console such that the rate could be decreased to 20 cycles/min. Hemodynamic measurements were recorded as the device rate was decreased. A repeat exercise test was then performed if the patient remained hemodynamically stable. A retrospective chart review of 111 LVAD recipients at our institution identified only 5 successful explant patients. Eighteen of the 39 patients were studied. Fifteen patients exercised with maximal device support. At peak exercise, V̇ o 2 averaged 14.5±3.6 mL · kg −1 · min −1 ; LVAD flow, 8.0±1.3 L/min; Fick cardiac output, 11.4±3.3 L/min; and pulmonary capillary wedge pressure, 13±4 mm Hg. Seven patients remained normotensive and could exercise at a fixed rate of 20 cycles/min. In these patients, peak V̇ o 2 declined from 17.3±3.9 to 13.0±6.1 mL · kg −1 · min −1 . In one of these patients, the device was explanted. Conclusions —Significant myocardial recovery after LVAD therapy in patients with end-stage congestive heart failure occurs in a small percentage of patients. Most of these patients have dilated cardiomyopathy. Exercise testing may be a useful modality to identify those patients in whom the device can be explanted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.22.2383

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 412

Metadata

Authors
Mancini, D. M., Beniaminovitz, A., Levin, H., Catanese, K., Flannery, M., DiTullio, M., Savin, S., Cordisco, M. E., Rose, E., & Oz, M.
Venue
Circulation
Published
1998-12
Volume
98
Issue
22
Pages
2383-2389
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2065756510
Cited by
412
References
1
FWCI
17.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low Incidence of Myocardial Recovery After Left Ventricular Assist Device Implantation in Patients With Chronic Heart Failure. https://app.cochat.ai/papers/10.1161/01.cir.98.22.2383
The paper
Mancini, D. M., Beniaminovitz, A., Levin, H., Catanese, K., Flannery, M., DiTullio, M., Savin, S., Cordisco, M. E., Rose, E., & Oz, M. (1998). Low Incidence of Myocardial Recovery After Left Ventricular Assist Device Implantation in Patients With Chronic Heart Failure. Circulation. https://doi.org/10.1161/01.cir.98.22.2383

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.