The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Low Incidence of Myocardial Recovery After Left Ventricular Assist Device Implantation in Patients With Chronic Heart Failure
Abstract
Background —Mechanical, histological, and biochemical improvement has been described in patients after left ventricular assist device (LVAD) support. Explantation of the LVADs without heart transplantation has been described in selected patients who received this therapy as a bridge to transplantation. Methods and Results —A retrospective review of patients receiving a mechanical bridge to transplantation at Columbia Presbyterian Hospital after July 21, 1991, was performed to determine the incidence of patients in whom the device was successfully explanted. From August 1, 1996, to February 1, 1998, we prospectively attempted to identify potential explant candidates by the use of exercise testing. During this time, we recruited 39 consecutive patients after insertion of the Thermo Cardiosystems vented electric device to participate in the following study. Approximately 3 months after device implantation, a maximal exercise test with hemodynamic monitoring and respiratory gas analysis was performed with the LVAD in the automated mode. The electric device was interfaced with a pneumatic console such that the rate could be decreased to 20 cycles/min. Hemodynamic measurements were recorded as the device rate was decreased. A repeat exercise test was then performed if the patient remained hemodynamically stable. A retrospective chart review of 111 LVAD recipients at our institution identified only 5 successful explant patients. Eighteen of the 39 patients were studied. Fifteen patients exercised with maximal device support. At peak exercise, V̇ o 2 averaged 14.5±3.6 mL · kg −1 · min −1 ; LVAD flow, 8.0±1.3 L/min; Fick cardiac output, 11.4±3.3 L/min; and pulmonary capillary wedge pressure, 13±4 mm Hg. Seven patients remained normotensive and could exercise at a fixed rate of 20 cycles/min. In these patients, peak V̇ o 2 declined from 17.3±3.9 to 13.0±6.1 mL · kg −1 · min −1 . In one of these patients, the device was explanted. Conclusions —Significant myocardial recovery after LVAD therapy in patients with end-stage congestive heart failure occurs in a small percentage of patients. Most of these patients have dilated cardiomyopathy. Exercise testing may be a useful modality to identify those patients in whom the device can be explanted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.
Devereux, R. B., & Reichek, N. (1977) · Circulation · doi:10.1161/01.cir.55.4.613 · Cited by 4,485
A Clinical Trial of Immunosuppressive Therapy for Myocarditis
Mason, J. W., O'Connell, J. B., Herskowitz, A., Rose, N. R., McManus, B. M., Billingham, M. E., & Moon, T. E. (1995) · New England Journal of Medicine · doi:10.1056/nejm199508033330501 · Cited by 1,274
Dec, G. W., Palacios, I. F., Fallon, J. T., Aretz, H. T., Mills, J., Lee, D. C.-S., & Johnson, R. A. (1985) · New England Journal of Medicine · doi:10.1056/nejm198504043121404 · Cited by 566
Levin, H. R., Oz, M. C., Chen, J. M., Packer, M., Rose, E. A., & Burkhoff, D. (1995) · Circulation · doi:10.1161/01.cir.91.11.2717 · Cited by 423
Self-citationImproved Left Ventricular Function After Chronic Left Ventricular Unloading
Frazier, O. H., Benedict, C. R., Radovancevic, B., Bick, R. J., Capek, P., Springer, W. E., Macris, M. P., Delgado, R., & Buja, L. M. (1996) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(96)00437-7 · Cited by 370
Prediction of improvement in recent oncet cardiomyopathy after referral for heart transplantation
Steimle, A. E., Stevenson, L. W., Fonarow, G. C., Hamilton, M. A., & Moriguchi, J. D. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90735-8 · Cited by 158
Potential of left ventricular assist devices as outpatient therapy while awaiting transplantation
Levin, H. R., Chen, J. M., Oz, M. C., Catanese, K. A., Krum, H., Goldsmith, R. L., Packer, M., & Rose, E. A. (1994) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(94)91946-1 · Cited by 84
Self-citationEffects of Exercise During Long-term Support With a Left Ventricular Assist Device
Jaski, B. E., Kim, J., Maly, R. S., Branch, K. R., Adamson, R. M., Favrot, L. K., Smith, S. C., & Dembitsky, W. P. (1997) · Circulation · doi:10.1161/01.cir.95.10.2401 · Cited by 60
Esophageal surgery at the end of the millennium
Lerut, A. (1998) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70237-5 · Cited by 48
Cited by
Feldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Left Ventricular Assist Device and Drug Therapy for the Reversal of Heart Failure
Birks, E. J., Tansley, P. D., Hardy, J., George, R. S., Bowles, C. T., Burke, M., Banner, N. R., Khaghani, A., & Yacoub, M. H. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa053063 · Cited by 885
Calcium Cycling in Congestive Heart Failure
Hasenfuss, G., & Pieske, B. (2002) · Journal of Molecular and Cellular Cardiology · doi:10.1006/jmcc.2002.2037 · Cited by 412
Maybaum, S., Mancini, D., Xydas, S., Starling, R. C., Aaronson, K., Pagani, F. D., Miller, L. W., Margulies, K., McRee, S., Frazier, O. H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.633180 · Cited by 399
Self-citationStainback, R. F., Estep, J. D., Agler, D. A., Birks, E. J., Bremer, M., Hung, J., Kirkpatrick, J. N., Rogers, J. G., & Shah, N. R. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.05.008 · Cited by 323
Metadata
- Authors
- Mancini, D. M., Beniaminovitz, A., Levin, H., Catanese, K., Flannery, M., DiTullio, M., Savin, S., Cordisco, M. E., Rose, E., & Oz, M.
- Venue
- Circulation
- Published
- 1998-12
- Volume
- 98
- Issue
- 22
- Pages
- 2383-2389
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2065756510
- Cited by
- 412
- References
- 9
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.