The DOI matches its Crossref record.
Mechanisms of Sustained Ventricular Tachycardia in Myotonic Dystrophy: Implications for Catheter Ablation
Open accessAbstract
Background —Ventricular arrhythmias have been documented and linked to the high incidence of sudden death seen in patients with myotonic dystrophy. However, their precise mechanism is unknown, and their definitive therapy remains to be established. Methods and Results —We studied 6 consecutive patients with myotonic dystrophy and sustained ventricular tachycardia by means of cardiac electrophysiological testing. Particular attention was paid to establish whether bundle-branch reentry was the tachycardia mechanism, and when such was the case, radiofrequency catheter ablation of either the right or left bundle branch was performed. Clinical tachycardia was inducible in all patients and had a bundle-branch reentrant mechanism. In 1 patient, 2 other morphologies of sustained tachycardia were also inducible, neither of which had ever been clinically documented, and both had a bundle-branch reentrant mechanism. Ventricular tachycardia was no longer inducible after bundle-branch ablation, except for a nonclinically documented and nonsustained ventricular tachycardia in the only patient who had apparent structural heart disease. Conclusions —A high clinical suspicion of bundle-branch reentrant tachycardia is justified in patients with myotonic dystrophy who exhibit wide QRS complex tachycardia or tachycardia-related symptoms. Because catheter ablation will easily and effectively abolish bundle-branch reentrant tachycardia, myotonic dystrophy should always be considered in patients with sustained ventricular tachycardia. This is especially true if no apparent heart disease is found.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Electrocardiographic Abnormalities and Sudden Death in Myotonic Dystrophy Type 1
Groh, W. J., Groh, M. R., Saha, C., Kincaid, J. C., Simmons, Z., Ciafaloni, E., Pourmand, R., Otten, R. F., Bhakta, D., Nair, G. V., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa062800 · Cited by 511
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000548 · Cited by 412
Metadata
- Authors
- Merino, J. L., Carmona, J. R., Fernández-Lozano, I., Peinado, R., Basterra, N., & Sobrino, J. A.
- Venue
- Circulation
- Published
- 1998-08-11
- Volume
- 98
- Issue
- 6
- Pages
- 541-546
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2148479689
- Cited by
- 168
- References
- 0
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanisms of Sustained Ventricular Tachycardia in Myotonic Dystrophy: Implications for Catheter Ablation. https://app.cochat.ai/papers/10.1161/01.cir.98.6.541
- The paper
- Merino, J. L., Carmona, J. R., Fernández-Lozano, I., Peinado, R., Basterra, N., & Sobrino, J. A. (1998). Mechanisms of Sustained Ventricular Tachycardia in Myotonic Dystrophy: Implications for Catheter Ablation. Circulation. https://doi.org/10.1161/01.cir.98.6.541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.