Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Evidence for a Central Origin of the Low-Frequency Oscillation in RR-Interval Variability

Cooley, Ryan L., Montano, Nicola, Cogliati, Chiara, van de Borne, Philippe, Richenbacher, Wayne, Oren, Ron, Somers, Virend K. · 1998 · Circulation

Abstract

Background —Short-term variability of RR interval and blood pressure occurs predominantly at low frequency (LF; ≈0.1 Hz) and high frequency (≈0.25 Hz). The arterial baroreflex is thought to be the predominant determinant of the LF component of RR variability. Patients with severe congestive heart failure (CHF) have an attenuated or absent LF oscillation in RR variability. The left ventricular assist device (LVAD) offers a unique possibility for analysis of spectral oscillations in RR interval independent of any effects of blood pressure that influence these oscillations via the baroreflex. Methods and Results —We performed spectral analysis of RR, blood pressure, and respiration in 2 patients with CHF before and after LVAD implantation. LF components of the RR-interval and blood pressure variability were absent in both CHF patients before LVAD implantation. After LVAD implantation, spectral analysis of the RR interval showed restoration of a clear and predominant LF oscillation in the native hearts of both patients, with no such oscillation evident in the blood pressure profile. Conclusions —During total circulatory support with the LVAD, the LF oscillation in RR interval of the native heart, absent in CHF, is restored. This LF oscillation in RR interval occurs in the absence of LF oscillations in blood pressure and thus is unlikely to be explained by baroreflex mechanisms. Hence, the absence of LF oscillation in the RR interval in CHF is functional and is reversible by LVAD circulation. The presence of a predominant LF oscillation in RR interval independent of any oscillation in blood pressure suggests that the LF oscillation is a fundamental property of central autonomic outflow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.6.556

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 173

Metadata

Authors
Cooley, R. L., Montano, N., Cogliati, C., van de Borne, P., Richenbacher, W., Oren, R., & Somers, V. K.
Venue
Circulation
Published
1998-08-11
Volume
98
Issue
6
Pages
556-561
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1999639121
Cited by
173
References
5
FWCI
7.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evidence for a Central Origin of the Low-Frequency Oscillation in RR-Interval Variability. https://app.cochat.ai/papers/10.1161/01.cir.98.6.556
The paper
Cooley, R. L., Montano, N., Cogliati, C., van de Borne, P., Richenbacher, W., Oren, R., & Somers, V. K. (1998). Evidence for a Central Origin of the Low-Frequency Oscillation in RR-Interval Variability. Circulation. https://doi.org/10.1161/01.cir.98.6.556

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.