The DOI matches its Crossref record.
Pulmonary Atresia With Intact Ventricular Septum: Impact of Fetal Echocardiography on Incidence at Birth and Postnatal Outcome
Abstract
Background —Fetal echocardiography is widely established in the United Kingdom for prenatal diagnosis of congenital heart disease. This may result in a substantial reduction in incidence at birth because of selected termination of pregnancy. The objective of this population-based study was to determine the incidence of pulmonary atresia with intact ventricular septum (PAIVS) at birth, the impact of fetal echocardiography on this incidence, and to compare the outcome of cases with and those without prenatal diagnosis. Methods and Results —From 1991 to 1995, all infants born with PAIVS and all fetal diagnoses in the United Kingdom and Eire were studied. There were 183 live births (incidence 4.5/100 000 live births). The incidence was 4.1 cases per 100 000 live births in England and Wales, 4.7 in Scotland, 6.8 in Eire, and 9.6 in Northern Ireland ( P =0.01). There were 86 fetal diagnoses made at a mean of 22.0 weeks of gestation leading to 53 terminations of pregnancy (61%), 4 intrauterine deaths (5%), and 29 live births (34%). The incidence at birth would be 5.6 per 100 000 births in England and Wales, 5.3 in Scotland, and unchanged in Eire and Northern Ireland, if there were no terminations of pregnancy and assuming no further spontaneous fetal deaths ( P =0.28). An initial diagnosis of critical pulmonary stenosis was made in 6 cases, at a mean of 22.3 weeks of gestation with progression to PAIVS by 31.4 weeks. Probability of survival at 1 year was 65% and was the same for live-born infants whether or not a fetal diagnosis had been made. Conclusions —PAIVS is rare, occurring in 1 in 22 000 live births in the United Kingdom and Eire. Termination of pregnancy has resulted in an important reduction in the live-born incidence in mainland Britain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The incidence of congenital heart disease.
Hoffman, J. I. E., & Kaplan, S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01886-7 · Cited by 6,099
Development of Z‐scores for fetal cardiac dimensions from echocardiography
Schneider, C., McCrindle, B. W., Carvalho, J. S., Hornberger, L. K., McCarthy, K. P., & Daubeney, P. E. F. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2597 · Cited by 314
Self-citationKumar, R. K., Newburger, J. W., Gauvreau, K., Kamenir, S. A., & Hornberger, L. K. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00172-1 · Cited by 305
Holland, B. J., Myers, J. A., & Woods, C. R. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14882 · Cited by 286
Lytzen, R., Vejlstrup, N., Bjerre, J., Petersen, O. B., Leenskjold, S., Dodd, J. K., Jørgensen, F. S., & Søndergaard, L. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.2009 · Cited by 169
Metadata
- Authors
- Daubeney, P. E. F., Sharland, G. K., Cook, A. C., Keeton, B. R., Anderson, R. H., & Webber, S. A.
- Venue
- Circulation
- Published
- 1998-08-11
- Volume
- 98
- Issue
- 6
- Pages
- 562-566
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2956095917
- Cited by
- 193
- References
- 0
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Atresia With Intact Ventricular Septum: Impact of Fetal Echocardiography on Incidence at Birth and Postnatal Outcome. https://app.cochat.ai/papers/10.1161/01.cir.98.6.562
- The paper
- Daubeney, P. E. F., Sharland, G. K., Cook, A. C., Keeton, B. R., Anderson, R. H., & Webber, S. A. (1998). Pulmonary Atresia With Intact Ventricular Septum: Impact of Fetal Echocardiography on Incidence at Birth and Postnatal Outcome. Circulation. https://doi.org/10.1161/01.cir.98.6.562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.