The DOI matches its Crossref record.
Simultaneous Endocardial Mapping in the Human Left Ventricle Using a Noncontact Catheter: Comparison of Contact and Reconstructed Electrograms During Sinus Rhythm
Open accessAbstract
Background —Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and morphology of reconstructed unipolar electrograms compared with contact unipolar electrograms from the same endocardial site. Methods and Results —The MEA was deployed in the left ventricles of 13 patients (end-diastolic diameters, 61.7±8.4 mm [mean±SD]). We recorded contact electrograms at 76 points equatorial and 32 points nonequatorial to the MEA during sinus rhythm using a catheter-locator signal to record direction and distance from the MEA. Morphology (cross-correlation) and timing of maximum −dV/dt of contact and reconstructed electrograms were compared at different distances from the MEA center to endocardium (M-E) and from the MEA equatorial plane. For equatorial data, the M-E was 32.12±12.12 mm. The timing of reconstructed with respect to contact electrograms was −1.94±7.12 ms for M-E <34 mm and −14.16±19.29 ms at M-E >34 mm ( P <0.001). Cross-correlation of electrograms was 0.87±0.12 (95% CI, 0.84 to 0.91) and 0.76±0.18 (95% CI, 0.69 to 0.83) for M-E <34 mm and >34 mm, respectively. Nonequatorial points were 32.33±10.81 mm (range, 16.9 to 55.6 mm) from the MEA equatorial plane; electrogram timing difference was −8.97±15.75 ms and was unrelated to this distance from the equator. Conclusions —This noncontact mapping system accurately reconstructs endocardial unipolar electrograms from the human left ventricle. At M-E distances >34 mm, timing accuracy of reconstruction decreases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationAuricchio, A., Fantoni, C., Regoli, F., Carbucicchio, C., Goette, A., Geller, C., Kloss, M., & Klein, H. (2004) · Circulation · doi:10.1161/01.cir.0000118502.91105.f6 · Cited by 585
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Characterization of Left Atrial Activation in the Intact Human Heart
Markides, V., Schilling, R. J., Yen Ho, S., Chow, A. W. C., Davies, D. W., & Peters, N. S. (2003) · Circulation · doi:10.1161/01.cir.0000048140.31785.02 · Cited by 284
Self-citationModification and ablation for inappropriate sinus tachycardia: current status
Shen, W.-K. (2002) · Cardiac Electrophysiology Review · doi:10.1023/a:1021167821190 · Cited by 39
Metadata
- Authors
- Schilling, R. J., Peters, N. S., & Davies, D. W.
- Venue
- Circulation
- Published
- 1998-09
- Volume
- 98
- Issue
- 9
- Pages
- 887-898
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2068944135
- Cited by
- 309
- References
- 0
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Endocardial Mapping in the Human Left Ventricle Using a Noncontact Catheter: Comparison of Contact and Reconstructed Electrograms During Sinus Rhythm. https://app.cochat.ai/papers/10.1161/01.cir.98.9.887
- The paper
- Schilling, R. J., Peters, N. S., & Davies, D. W. (1998). Simultaneous Endocardial Mapping in the Human Left Ventricle Using a Noncontact Catheter: Comparison of Contact and Reconstructed Electrograms During Sinus Rhythm. Circulation. https://doi.org/10.1161/01.cir.98.9.887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.