The DOI matches its Crossref record.
Doppler Estimation of Left Ventricular Filling Pressures in Patients With Hypertrophic Cardiomyopathy
Open accessAbstract
Background —Conventional Doppler parameters are unreliable for estimating left ventricular (LV) filling pressures in hypertrophic cardiomyopathy (HCM). This study was undertaken to evaluate flow propagation velocity by color M-mode and early diastolic annular velocity (Ea) by tissue Doppler 2 new indices of LV relaxation, combined with mitral E velocity for estimation of filling pressures in HCM. Methods and Results —Thirty-five HCM patients (52±15 years) underwent LV catheterization simultaneously with 2-dimensional and Doppler echocardiography. Pulsed Doppler echocardiography of mitral and pulmonary venous flows was obtained along with flow propagation velocity and Ea. LV preA pressure had weak or no relations with mitral, pulmonary venous velocities and atrial volumes. In contrast, preA pressure related strongly to E velocity/flow propagation velocity ( r =0.67; SEE=4) and E/Ea ( r =0.76; SEE=3.4). In 17 patients with repeat measurements, preA pressure changes were well detected by measuring E velocity/flow propagation velocity ( r =0.68; P =0.01) or E/Ea ( r =0.8; P <0.001). PreA pressure estimation with these 2 methods was tested prospectively in 17 additional HCM patients with good results (E velocity/flow propagation velocity, r =0.76; E/Ea, r =0.82). Conclusions —LV filling pressures can be estimated with reasonable accuracy in HCM patients by measuring E velocity/flow propagation velocity or E/Ea. These ratios also track changes in filling pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Self-citationRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Self-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Self-citationOmmen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Nagueh, S. F., Bachinski, L. L., Meyer, D., Hill, R., Zoghbi, W. A., Tam, J. W., Quiñones, M. A., Roberts, R., & Marian, A. J. (2001) · Circulation · doi:10.1161/01.cir.104.2.128 · Cited by 616
Self-citation
Metadata
- Authors
- Nagueh, S. F., Lakkis, N. M., Middleton, K. J., Spencer, W. H., Zoghbi, W. A., & Quiñones, M. A.
- Venue
- Circulation
- Published
- 1999-01-19
- Volume
- 99
- Issue
- 2
- Pages
- 254-261
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1994771690
- Cited by
- 530
- References
- 0
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Doppler Estimation of Left Ventricular Filling Pressures in Patients With Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.99.2.254
- The paper
- Nagueh, S. F., Lakkis, N. M., Middleton, K. J., Spencer, W. H., Zoghbi, W. A., & Quiñones, M. A. (1999). Doppler Estimation of Left Ventricular Filling Pressures in Patients With Hypertrophic Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.99.2.254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).