The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Left Ventricular Diastolic Function in Normal Human Pregnancy
Open accessAbstract
Background —Little information is available about changes in left ventricular diastolic function during pregnancy. We used mitral inflow and pulmonary venous flow profiles to evaluate left ventricular diastolic function in 37 healthy pregnant women 26 to 41 years old (mean, 32 years). Methods and Results —Echocardiographic studies were performed at the end of each trimester. Eight subjects (control group) underwent similar testing 1 to 3.5 months (mean, 1.7 months) postpartum. During pregnancy, the cardiac output increased significantly as a result of an increased heart rate and, to a lesser degree, stroke volume. Significantly decreased systemic vascular resistance and increased left ventricular mass were also noted. Peak mitral flow velocity in early diastole (E) increased 13.3% during the first trimester and remained at the high end of normal throughout pregnancy. Peak A-wave velocity (A) increased maximally in the third trimester. Compared with control subjects, first-trimester subjects had a significantly increased E/A ratio. The ratio subsequently decreased, reflecting the augmented A-wave velocity. Pulmonary venous peak systolic forward flow velocity increased, peaking in the second trimester (nonsignificant), but returned to baseline levels postpartum. The pulmonary venous diastolic time-velocity integral decreased significantly from the first to the third trimester. Peak pulmonary venous reverse flow velocity at atrial contraction increased significantly, without being markedly changed in duration. Conclusions —Pregnancy, a chronic, natural volume-overload state, has important effects on hemodynamic and echocardiographic variables. Based on pulmonary venous flow and left ventricular inflow velocities, our results provide a standard reference concerning diastolic filling dynamics by trimester.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Left Ventricular Hypertrophy: Pathogenesis, Detection, and Prognosis
Lorell, B. H., & Carabello, B. A. (2000) · Circulation · doi:10.1161/01.cir.102.4.470 · Cited by 1,232
Abduljalil, K., Furness, P., Johnson, T. N., Rostami-Hodjegan, A., & Soltani, H. (2012) · Clinical Pharmacokinetics · doi:10.2165/11597440-000000000-00000 · Cited by 371
Metadata
- Authors
- Mesa, A., Jessurun, C., Hernandez, A., Adam, K., Brown, D., Vaughn, W. K., & Wilansky, S.
- Venue
- Circulation
- Published
- 1999-02-02
- Volume
- 99
- Issue
- 4
- Pages
- 511-517
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2007876198
- Cited by
- 216
- References
- 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left Ventricular Diastolic Function in Normal Human Pregnancy. https://app.cochat.ai/papers/10.1161/01.cir.99.4.511
- The paper
- Mesa, A., Jessurun, C., Hernandez, A., Adam, K., Brown, D., Vaughn, W. K., & Wilansky, S. (1999). Left Ventricular Diastolic Function in Normal Human Pregnancy. Circulation. https://doi.org/10.1161/01.cir.99.4.511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.