Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Left Ventricular Diastolic Function in Normal Human Pregnancy

Open access
Mesa, Andres, Jessurun, Carlos, Hernandez, Antonieta, Adam, Karolina, Brown, Dale, Vaughn, William K., Wilansky, Susan·1999·Circulation

Abstract

Background —Little information is available about changes in left ventricular diastolic function during pregnancy. We used mitral inflow and pulmonary venous flow profiles to evaluate left ventricular diastolic function in 37 healthy pregnant women 26 to 41 years old (mean, 32 years). Methods and Results —Echocardiographic studies were performed at the end of each trimester. Eight subjects (control group) underwent similar testing 1 to 3.5 months (mean, 1.7 months) postpartum. During pregnancy, the cardiac output increased significantly as a result of an increased heart rate and, to a lesser degree, stroke volume. Significantly decreased systemic vascular resistance and increased left ventricular mass were also noted. Peak mitral flow velocity in early diastole (E) increased 13.3% during the first trimester and remained at the high end of normal throughout pregnancy. Peak A-wave velocity (A) increased maximally in the third trimester. Compared with control subjects, first-trimester subjects had a significantly increased E/A ratio. The ratio subsequently decreased, reflecting the augmented A-wave velocity. Pulmonary venous peak systolic forward flow velocity increased, peaking in the second trimester (nonsignificant), but returned to baseline levels postpartum. The pulmonary venous diastolic time-velocity integral decreased significantly from the first to the third trimester. Peak pulmonary venous reverse flow velocity at atrial contraction increased significantly, without being markedly changed in duration. Conclusions —Pregnancy, a chronic, natural volume-overload state, has important effects on hemodynamic and echocardiographic variables. Based on pulmonary venous flow and left ventricular inflow velocities, our results provide a standard reference concerning diastolic filling dynamics by trimester.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.99.4.511

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mesa, A., Jessurun, C., Hernandez, A., Adam, K., Brown, D., Vaughn, W. K., & Wilansky, S.
Venue
Circulation
Published
1999-02-02
Volume
99
Issue
4
Pages
511-517
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2007876198
Cited by
216
References
1
FWCI
3.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular Diastolic Function in Normal Human Pregnancy. https://app.cochat.ai/papers/10.1161/01.cir.99.4.511
The paper
Mesa, A., Jessurun, C., Hernandez, A., Adam, K., Brown, D., Vaughn, W. K., & Wilansky, S. (1999). Left Ventricular Diastolic Function in Normal Human Pregnancy. Circulation. https://doi.org/10.1161/01.cir.99.4.511

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.