Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Rapid Platelet-Function Assay: An Automated and Quantitative Cartridge-Based Method

Smith, Jeffrey W., Steinhubl, Steven R., Lincoff, A. Michael, Coleman, Jacqueline C., Lee, Theodore T., Hillman, Robert S., Coller, Barry S. · 1999 · Circulation

Abstract

Background —The platelet glycoprotein (GP) IIb/IIIa receptor is important in mediating platelet thrombus formation, and the GP IIb/IIIa antagonist abciximab (c7E3 Fab; ReoPro) is effective in preventing thrombotic ischemic cardiovascular complications of unstable angina and percutaneous coronary interventions. Small-molecule antagonists of GP IIb/IIIa based on the Arg-Gly-Asp (RGD) sequence show similar benefit, and some of these agents are orally active. However, there may be significant interindividual variation in response to such antagonists, especially with chronic oral therapy. It will be essential to balance the beneficial antithrombotic effect of these drugs with their potential for causing bleeding. In response to this need, we have developed a rapid platelet-function assay (RPFA), a point-of-care system that provides a quantitative measure of the competence of the GP IIb/IIIa receptor as reflected in the ability of platelets to agglutinate fibrinogen-coated beads. Methods and Results —Polystyrene beads were coated with fibrinogen and placed in a cartridge along with a lyophilized peptide that activates the thrombin receptor. Anticoagulated whole blood was added to the cartridge, and then a microprocessor-controlled operation mixed the reagents and detected agglutination between platelets and coated beads. Quantitative digital results were displayed within 3 minutes. Because there is no dilution of the blood, the assay can be used to measure platelet activity in samples that have been treated with GP IIb/IIIa antagonists with high dissociation rates. RPFA results of whole-blood samples treated with different GP IIb/IIIa antagonists correlated well with both conventional turbidimetric platelet aggregation ( r 2 =0.95) and the percentage of free GP IIb/IIIa molecules in the sample ( r 2 =0.96). The mean difference in measurements between RPFA and aggregometry was –4% (±4% SD), and the mean difference in measurements between RPFA and free GP IIb/IIIa receptors was –2% (±6% SD). Conclusions —The RPFA provides rapid information on platelet function that mirrors turbidimetric platelet aggregation and reflects GP IIb/IIIa receptor blockade.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.99.5.620

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 274

Metadata

Authors
Smith, J. W., Steinhubl, S. R., Lincoff, A. M., Coleman, J. C., Lee, T. T., Hillman, R. S., & Coller, B. S.
Venue
Circulation
Published
1999-02-09
Volume
99
Issue
5
Pages
620-625
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2031182983
Cited by
274
References
3
FWCI
11.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid Platelet-Function Assay: An Automated and Quantitative Cartridge-Based Method. https://app.cochat.ai/papers/10.1161/01.cir.99.5.620
The paper
Smith, J. W., Steinhubl, S. R., Lincoff, A. M., Coleman, J. C., Lee, T. T., Hillman, R. S., & Coller, B. S. (1999). Rapid Platelet-Function Assay: An Automated and Quantitative Cartridge-Based Method. Circulation. https://doi.org/10.1161/01.cir.99.5.620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.