Crossover design to test antihypertensive drugs with self-recorded blood pressure.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In a double-blind, within-patient study, blood pressure was measured at regular intervals at the clinic by the physician and each day at home by the patient. Both methods of blood pressure measurement demonstrated an antihypertensive effect of the diuretics chlorthalidone (25 mg) and triamterene (50 mg) and the beta-blocker oxprenolol (160 mg) and the greater efficacy of the combination of the two therapies. During placebo, as well as during active treatment, blood pressure values were higher at the clinic than at home, except when the patients were taking the beta-blocker, which minimized the arousal response during blood pressure measurements in the clinic. With 2-week treatment periods, separated by 2 weeks of placebo administration, blood pressure returned toward its initial level after each of the three treatments and none of the carryover effects was significant at the 5% level. This methodology was intended to make it possible to demonstrate in 27 patients at the clinic and in 20 patients with measurements made at home, at the usual statistical risks (alpha = 5%, beta = 10%), a fall of 5 mm Hg in diastolic blood pressure in comparison with a placebo. Moreover, at the end of this 3-month follow-up, each patient could continue to receive the treatment that was the most effective and the best tolerated. In conclusion, the use of a within-patient trial design, with a 15-day washout period between active treatments and careful recording of blood pressure values, can minimize the number of patients included in hypertension trials and offer to each patient the possibility of individualization of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 472
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Ferrario, C. M., Trask, A. J., & Jessup, J. A. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00618.2005 · Cited by 385
Santos, R. A. S., Campagnole-Santos, M. J., & Andrade, S. P. (2000) · Regulatory Peptides · doi:10.1016/s0167-0115(00)00138-5 · Cited by 380
Reliability of reporting self-measured blood pressure values by hypertensive patients
MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00241-6 · Cited by 268
Metadata
- Authors
- Ménard, J., Serrurier, D., Bautier, P., Plouin, P. F., & Corvol, P.
- Venue
- Hypertension
- Published
- 1988-02
- Volume
- 11
- Issue
- 2
- Pages
- 153-159
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2063532711
- Cited by
- 69
- References
- 1
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.