The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Reliability of reporting self-measured blood pressure values by hypertensive patients
Open accessAbstract
For self-measurement of blood pressure to be useful, patient reporting of test results must be reliable and accurate. Until now no study directly measured the accuracy and reliability of patients' reporting of self-measured blood pressure values. Thirty hypertensive patients (69 +/- 11 years) were instructed to measure blood pressure at home over 14 days with the highly accurate Omron IC monitor and to keep a record of all readings in a patient logbook. To assess the reliability of the records, patients were not informed about the memory capacity of the device. We compared automatically stored blood pressure readings with the respective logbook entries to analyze deletion (under-reporting), addition (over-reporting), and precision of reporting of test results. The prevalent pattern was under-reporting, averaging 36% +/- 24% (3% to 89%), which occurred significantly more than over-reporting (9% +/- 11%; 0% to 38%). The precision of reporting (identical values at corresponding times) was 76% +/- 34% (0% to 100%). This observer error did not affect group comparisons of automatically stored values and logbook entries, although the estimated limits of agreement were wide. Blood pressure control, duration of hypertension, age, or previous use of self-measurement and patterns of logbook entries were not found to be predictive of the patients' reliability. Our results demonstrate a substantial observer error in the reporting of self-measured blood pressure values. This bias may be reduced by memory-equipped blood pressure devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 472
O'Brien, E. T., Mee, F. I., Atkins, N., & Thomas (1996) · PubMed · Cited by 409
Reliability of blood glucose monitoring by patients with diabetes mellitus
Mazze, R. S., Shamoon, H., Pasmantier, R., Lucido, D., Murphy, J., Hartmann, K., Kuykendall, V., & Lopatin, W. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90693-4 · Cited by 261
Observer bias in blood pressure studies
Bruce, N. G., Shaper, A. G., Walker, M., & Wannamethee, G. (1988) · Journal of Hypertension · doi:10.1097/00004872-198805000-00006 · Cited by 144
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Mengden, T., Binswanger, B., Spühler, T., Weisser, B., & Vetter, W. (1993) · Journal of Hypertension · doi:10.1097/00004872-199312000-00013 · Cited by 95
Self-citationCrossover design to test antihypertensive drugs with self-recorded blood pressure.
Ménard, J., Serrurier, D., Bautier, P., Plouin, P., & Corvol, P. L. (1988) · Hypertension · doi:10.1161/01.hyp.11.2.153 · Cited by 68
Mengden, T., Bättig, B., & Vetter, W. (1991) · Journal of Hypertension · doi:10.1097/00004872-199112000-00152 · Cited by 45
Self-citationWeisser, B., Grune, S., Burger, R., Blickenstorfer, H., Iseli, J., Michelsen, S. H., Opravil, R., Rageth, S., Sturzenegger, E., & Walker, P. (1994) · PubMed · Cited by 40
[How reliable is conventional blood pressure registration? Comparison with a semi-automatic device].
Kolb, C., Huß, R., Mengden, T., & Vetter, W. (1991) · PubMed · Cited by 4
Self-citation
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Flynn, J. T., Kaelber, D. C., Baker-Smith, C. M., Blowey, D., Carroll, A. E., Daniels, S. R., de Ferranti, S. D., Dionne, J. M., Falkner, B., Flinn, S. K., et al. (2017) · Pediatrics · doi:10.1542/peds.2017-1904 · Cited by 3,651
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Metadata
- Authors
- MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-12
- Volume
- 11
- Issue
- 12
- Pages
- 1413-1417
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2143229385
- Cited by
- 268
- References
- 10
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of reporting self-measured blood pressure values by hypertensive patients. https://app.cochat.ai/papers/10.1016/s0895-7061(98)00241-6
- The paper
- MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H. (1998). Reliability of reporting self-measured blood pressure values by hypertensive patients. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(98)00241-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.