Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 268

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Reliability of reporting self-measured blood pressure values by hypertensive patients

Open access
MENGDEN, T, HERNANDEZMEDINA, R, BELTRAN, B, ALVAREZ, E, KRAFT, K, VETTER, H·1998·American Journal of Hypertension

Abstract

For self-measurement of blood pressure to be useful, patient reporting of test results must be reliable and accurate. Until now no study directly measured the accuracy and reliability of patients' reporting of self-measured blood pressure values. Thirty hypertensive patients (69 +/- 11 years) were instructed to measure blood pressure at home over 14 days with the highly accurate Omron IC monitor and to keep a record of all readings in a patient logbook. To assess the reliability of the records, patients were not informed about the memory capacity of the device. We compared automatically stored blood pressure readings with the respective logbook entries to analyze deletion (under-reporting), addition (over-reporting), and precision of reporting of test results. The prevalent pattern was under-reporting, averaging 36% +/- 24% (3% to 89%), which occurred significantly more than over-reporting (9% +/- 11%; 0% to 38%). The precision of reporting (identical values at corresponding times) was 76% +/- 34% (0% to 100%). This observer error did not affect group comparisons of automatically stored values and logbook entries, although the estimated limits of agreement were wide. Blood pressure control, duration of hypertension, age, or previous use of self-measurement and patterns of logbook entries were not found to be predictive of the patients' reliability. Our results demonstrate a substantial observer error in the reporting of self-measured blood pressure values. This bias may be reduced by memory-equipped blood pressure devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(98)00241-6

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 268

Metadata

Authors
MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H.
Venue
American Journal of Hypertension
Published
1998-12
Volume
11
Issue
12
Pages
1413-1417
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2143229385
Cited by
268
References
10
FWCI
5.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of reporting self-measured blood pressure values by hypertensive patients. https://app.cochat.ai/papers/10.1016/s0895-7061(98)00241-6
The paper
MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H. (1998). Reliability of reporting self-measured blood pressure values by hypertensive patients. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(98)00241-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.