Evaluation of the Technique Used by Health-Care Workers for Taking Blood Pressure
The DOI matches its Crossref record.
Abstract
The precise guidelines recommended by the American Heart Association for blood pressure measurement are commonly overlooked by health-care workers, who generally take blood pressure in an arbitrary way. To validate this observation we designed a descriptive and observational study to be carried out in a major hospital. One hundred and seventy-two health-care workers divided into four groups (63 general practitioners, 25 clinical and 25 surgical specialists, and 59 nurses) were evaluated in a two-part test. In the first part (practical), the examinee had to follow all the steps recommended by the American Heart Association to get a passing score. In the second part (theoretical, which came second to avoid influencing the practical), the examinee had to answer correctly 7 of 10 questions based on the American Heart Association’s guidelines to obtain a passing score. The highest accepted variation in systolic and diastolic pressures between examinee and observer was ±4 mm Hg. None of the examinees followed the American Heart Association’s recommendations. Sixty-three percent of systolic and 53% of diastolic readings were out of range. Surgical specialists obtained the best practical results (48% systolic and 64% diastolic within range), and nurses obtained the lowest values (29% and 39%, respectively; P =.03 versus surgical specialists). These two groups showed deficiencies in the theoretical test (nurses, 10% correct answers and surgical specialists, 16%). Clinical specialists obtained the best results on the theoretical test (60% correct; P <.05 versus the other groups) but were deficient in the practical test (32% systolic and 60% diastolic within range). In conclusion, on practical and theoretical bases health-care workers took blood pressure inaccurately and incorrectly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Principles and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Physician and Pharmacist Collaboration to Improve Blood Pressure Control
Carter, B. L. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.358 · Cited by 311
Metabolic Syndrome Among HIV-Infected Patients
Jericó, C., Knobel, H., Montero, M., Ordoñez-Llanos, J., Guelar, A., Gimeno, J. L., Saballs, P., López-Colomés, J. L., & Pedro-Botet, J. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.132 · Cited by 257
Boonyasai, R. T., Carson, K. A., Marsteller, J. A., Dietz, K. B., Noronha, G. J., Hsu, Y., Flynn, S. J., Charleston, J. M., Prokopowicz, G. P., Miller, E. R., et al. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13166 · Cited by 34
The Impact of Arm Position on the Measurement of Orthostatic Blood Pressure
Guss, D. A., Abdelnur, D., & Hemingway, T. J. (2008) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.05.049 · Cited by 15
Arm Position and Blood Pressure Measurement
Hemingway, T. J., Guss, D. A., & Abdelnur, D. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-1-200401060-00037 · Cited by 15
Metadata
- Authors
- Villegas, I., Arias, I. C., Botero, A., & Escobar, A.
- Venue
- Hypertension
- Published
- 1995-12
- Volume
- 26
- Issue
- 6
- Pages
- 1204-1206
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2107746949
- Cited by
- 102
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.