CoChat

Left Ventricular Filling in Arterial Hypertension: Influence of Obesity and Hemodynamic and Structural Confounders

Mureddu, Gian Francesco, de Simone, Giovanni, Greco, Rosanna, Rosato, Giuseppe Flavio, Contaldo, Franco · 1997 · Hypertension
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We assessed the relations of left ventricular filling to load and geometry by Doppler echocardiography in 80 normotensive subjects (40 normal-weight [36±12 years, 24 women] and 40 obese [35±13 years, 24 women]) and 61 hypertensive subjects without silent coronary heart disease (29 normal-weight [43±13 years, 15 women] and 32 obese [42±13 years, 19 women]) and comparable left ventricular midwall performance. Left ventricular mass divided by height to the 2.7 power was higher in all groups than in normotensive normal-weight subjects (all P <.0001) and in hypertensive than normotensive obese subjects ( P <.001). After controlling for age, sex, blood pressure, and heart rate, isovolumic relaxation time was prolonged in hypertensive subjects and normotensive obese subjects compared with normotensive normal-weight subjects (all P <.0001). Body mass index, left ventricular dimension and mass, and circumferential end-systolic stress did not influence these differences. In pooled groups, prolonged isovolumic relaxation time was predicted by high mean blood pressure (β=0.52, P <.001), low end-systolic stress (β=−0.33, P <.001), increased left ventricular mass (β=0.24, P <.004), and high body mass index (β=0.14, P <.05, multiple R =.72, SEE=16.5 milliseconds, P <.0001). Between-group differences in peak early transmitral flow velocity, the deceleration time of early filling velocity, and the ratio of early to late left ventricular filling disappeared after controlling for left ventricular mass. Thus, (1) isovolumic relaxation time is prolonged in both arterial hypertension and obesity; (2) the presence of obesity does not significantly increase isovolumic relaxation time in hypertension; and (3) abnormalities of left ventricular filling in arterial hypertension are offset after controlling for left ventricular mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.29.2.544

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Mureddu, G. F., de Simone, G., Greco, R., Rosato, G. F., & Contaldo, F.
Venue
Hypertension
Published
1997-02
Volume
29
Issue
2
Pages
544-550
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2104008867
Cited by
64
References
1
FWCI
2.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular Filling in Arterial Hypertension: Influence of Obesity and Hemodynamic and Structural Confounders. https://app.cochat.ai/papers/10.1161/01.hyp.29.2.544
The paper
Mureddu, G. F., de Simone, G., Greco, R., Rosato, G. F., & Contaldo, F. (1997). Left Ventricular Filling in Arterial Hypertension: Influence of Obesity and Hemodynamic and Structural Confounders. Hypertension. https://doi.org/10.1161/01.hyp.29.2.544

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.