Time-Voltage QRS Area of the 12-Lead Electrocardiogram: Detection of Left Ventricular Hypertrophy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract —Identification of left ventricular hypertrophy (LVH) using 12-lead ECG criteria based primarily on QRS amplitudes has been limited by poor sensitivity at acceptable levels of specificity. Because the product of QRS voltage and duration, as an approximation of the time-voltage area of the QRS complex, can improve accuracy of the 12-lead ECG for LVH, we examined the diagnostic value of true time-voltage area measurements of QRS complexes from the standard 12-lead ECG. Standard 12-lead ECGs and echocardiograms were obtained in 175 control subjects without LVH and in 74 patients with regurgitant valvular heart disease and LVH defined by echocardiographic criteria (indexed LV mass >110 g/m 2 in women and >125 g/m 2 in men). Standard voltage criteria, voltage-duration products (voltage multiplied by QRS duration), and true time-voltage areas of the QRS were calculated for Sokolow-Lyon criteria (SV 1 +RV 5/6 ) and the 12-lead sum of voltage criteria. Test sensitivities were compared using gender-specific partitions with matched specificity of 98% in the 175 subjects without LVH. Measurement of the time-voltage area significantly improved sensitivity for both criteria. The 76% sensitivity of the 12-lead sum area and 65% sensitivity of Sokolow-Lyon area were significantly greater than the 54% sensitivity of the approximation of QRS area provided by each voltage-duration product ( P <.001 and P =.021) and than the 46% and 43% sensitivities of the respective simple voltage criteria (each P <.001). Comparison of receiver operating characteristic curves confirmed the superior overall performance of time-voltage area criteria compared with both voltage-duration products and simple voltage criteria. These results suggest that use of time-voltage areas can dramatically improve identification of LVH by 12-lead ECG. Further study of this approach is needed to identify optimal criteria for LVH based on the time-voltage area measurements from the 12-lead ECG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Koren, M. J., Devereux, R. B., Casale, P. N., Savage, D. D., & Laragh, J. H. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-5-345 · Cited by 2,366
Self-citationPredictive Value of a Single Diagnostic Test in Unselected Populations
Vecchio, T. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742104 · Cited by 941
Cited by
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Self-citationKligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Okin, P. M. (2004) · JAMA · doi:10.1001/jama.292.19.2343 · Cited by 663
Self-citationKunutsor, S. K., Kurl, S., Zaccardi, F., & Laukkanen, J. A. (2016) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.12.020 · Cited by 58
Metadata
- Authors
- Okin, P. M., Roman, M. J., Devereux, R. B., Pickering, T. G., Borer, J. S., & Kligfield, P.
- Venue
- Hypertension
- Published
- 1998-04
- Volume
- 31
- Issue
- 4
- Pages
- 937-942
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2023914545
- Cited by
- 86
- References
- 3
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.