CoChat

Intravascular Source of Adenosine During Forearm Ischemia in Humans: Implications for Reactive Hyperemia

Open access
Costa, Fernando, Sulur, Paulgun, Angel, Mark, Cavalcante, José, Haile, Virginia, Christman, Brian, Biaggioni, Italo · 1999 · Hypertension
Cited by 56

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Abstract—It is believed that adenosine is released in ischemic tissues and contributes to reactive hyperemia. We tested this hypothesis in the human forearm using microdialysis to estimate interstitial and intravascular levels of adenosine and caffeine withdrawal to potentiate endogenous adenosine and determine its effect on reactive hyperemia. Forearm blood flow response to ischemia was measured by air plethysmography before and 60 hours after the last dose of caffeine (250 mg TID for 7 days, n=6). Forearm blood flow increased by 274±66% and 467±97% after 3 minutes of forearm ischemia, before and during caffeine withdrawal, respectively (P<0.05). Thus, caffeine withdrawal enhances reactive hyperemia. To determine the source of adenosine, we measured interstitial adenosine with the use of a microdialysis probe inserted into the flexor digitorum superficialis muscle of the forearm, and we measured intravascular adenosine with the use of a microdialysis probe inserted retrogradely into the medial cubital vein. Dialysate samples were collected at 15-minute intervals during resting, forearm ischemia, and recovery periods. Forearm ischemia failed to increase muscle dialysate concentrations of adenosine but did increase intravascular dialysate adenosine 2.1-fold, from 0.61±0.12 to 1.28±0.39 μmol/L (P<0.01, n=8). Intravascular dialysate concentrations of thromboxane B 2 did not increase during ischemia, ruling out platelet aggregation as a source of adenosine. These results support the hypothesis that endogenous adenosine contributes to reactive hyperemia and indicate that the major source of adenosine in the human forearm is intravascular. We speculate that endothelial cells are the source of intravascular adenosine during ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.33.6.1453

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Costa, F., Sulur, P., Angel, M., Cavalcante, J., Haile, V., Christman, B., & Biaggioni, I.
Venue
Hypertension
Published
1999-06
Volume
33
Issue
6
Pages
1453-1457
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2059518655
Cited by
56
References
1
FWCI
1.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.