Effects of Spinal Section and of Positive-Feedback Excitatory Reflex on Sympathetic and Heart Rate Variability
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract —The sympathetic outflow appears to be capable of displaying a rhythmicity synchronous with cardiovascular Mayer’s waves even after spinal section. To test the hypothesis that spinal sympathetic low frequency (LF) oscillation can be enhanced during sympathetic excitation, we recorded cardiac sympathetic nerve activity (SNA), R-R interval, arterial pressure, and ventilation in 9 unanesthetized decerebrate-vagotomized cats before and after C1 spinal section. LF and high frequency (HF) components were detected in the variability of SNA, R-R interval, and systolic arterial pressure both before and after spinal section. In this latter condition, a significant coherence between LF SNA and LF R-R was present in 5 animals, whereas HF SNA and HF R-R were correlated in 4 animals. During an excitatory sympathetic spinal reflex elicited by aortic constriction, the efferent sympathetic firing was markedly enhanced (from 7±2 to 33±7 spikes/s); concomitantly, the powers of both LF SNA and HF SNA were also increased. Coherence between LF SNA and LF R-R became significant in all cases, whereas HF SNA and HF R-R became correlated in 6 animals. In 3 animals, the reflex sympathetic excitation was no longer elicitable after interrupting a vast contingent of sympathetic afferents by means of thoracic dorsal root section. We report for the first time that LF and HF oscillations are detectable in SNA, R-R interval, and systolic arterial pressure variabilities of decerebrate-vagotomized spinal cats and that an excitatory spinal reflex is capable of increasing the power of both SNA spectral components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Self-citationMontano, N., Lombardi, F., Gnecchi Ruscone, T., Contini, M., Finocchiaro, M. L., Baselli, G., Porta, A., Cerutti, S., & Malliani, A. (1992) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(92)90222-3 · Cited by 97
Self-citation
Cited by
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
“1-Hz rhythm in the cardiac SNA of unanesthetized, decerebrate cats after bilateral vagotomy and C1 spinal section [38].”
BackgroundMontano, N., Porta, A., Cogliati, C., Costantino, G., Tobaldini, E., Casali, K. R., & Iellamo, F. (2009) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2008.07.006 · Cited by 458
Self-citationKetch, T., Biaggioni, I., Robertson, R., & Robertson, D. (2002) · Circulation · doi:10.1161/01.cir.0000017186.52382.f4 · Cited by 218
Heart rate variability and slow-paced breathing:when coherence meets resonance
Sevoz-Couche, C., & Laborde, S. (2022) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2022.104576 · Cited by 195
Heart rate variability: from bench to bedside
Malliani, A. (2005) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2004.06.016 · Cited by 182
Self-citation
Metadata
- Authors
- Montano, N., Cogliati, C., da Silva, V. J. D., Gnecchi-Ruscone, T., Massimini, M., Porta, A., & Malliani, A.
- Venue
- Hypertension
- Published
- 2000-12
- Volume
- 36
- Issue
- 6
- Pages
- 1029-1034
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2130114470
- Cited by
- 44
- References
- 2
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.