The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Ionic Current Basis of Electrocardiographic Waveforms: A Model Study
Open accessAbstract
Body surface electrocardiograms and electrograms recorded from the surfaces of the heart are the basis for diagnosis and treatment of cardiac electrophysiological disorders and arrhythmias. Given recent advances in understanding the molecular mechanisms of arrhythmia, it is important to relate these electrocardiographic waveforms to cellular electrophysiological processes. This modeling study establishes the following principles: (1) voltage gradients created by heterogeneities of the slow-delayed rectifier ( I Ks ) and transient outward ( I to ) potassium current inscribe the T wave and J wave, respectively; T-wave polarity and width are strongly influenced by the degree of intercellular coupling through gap-junctions. (2) Changes in [K + ] o modulate the T wave through their effect on the rapid-delayed rectifier, I Kr . (3) Alterations of I Ks , I Kr , and I Na (fast sodium current) in long-QT syndrome (LQT1, LQT2, and LQT3, respectively) are reflected in characteristic QT-interval and T-wave changes; LQT1 prolongs QT without widening the T wave. (4) Accelerated inactivation of I Na on the background of large epicardial I to results in ST elevation (Brugada phenotype) that reflects the degree of severity. (5) Activation of the ATP-sensitive potassium current, I K(ATP) , is sufficient to cause ST elevation during acute ischemia. These principles provide a mechanistic cellular basis for interpretation of electrocardiographic waveforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schwartz, P. J., Priori, S. G., Spazzolini, C., Moss, A. J., Vincent, G. M., Napolitano, C., Denjoy, I., Guicheney, P., Breithardt, G., Keating, M. T., et al. (2001) · Circulation · doi:10.1161/01.cir.103.1.89 · Cited by 1,779
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589
Self-citationYan, G.-X., & Antzelevitch, C. (1998) · Circulation · doi:10.1161/01.cir.98.18.1928 · Cited by 988
Cellular Basis for the Electrocardiographic J Wave
Yan, G.-X., & Antzelevitch, C. (1996) · Circulation · doi:10.1161/01.cir.93.2.372 · Cited by 812
Shaw, R. M., & Rudy, Y. (1997) · Circulation Research · doi:10.1161/01.res.81.5.727 · Cited by 670
Self-citationECG T-wave patterns in genetically distinct forms of the hereditary long QT syndrome
Moss, A. J., Zareba, W., Benhorin, J., Locati, E. H., Hall, W. J., Robinson, J. L., Schwartz, P. J., Towbin, J. A., Vincent, G. M., Lehmann, M. H., et al. (1995) · Circulation · doi:10.1161/01.cir.92.10.2929 · Cited by 616
The M Cell: Its Contribution to the ECG and to Normal and Abnormal Electrical Function of the Heart
ANTZELEVITCH, C., SHIMIZU, W., YAN, G., SICOURI, S., WEISSENBURGER, J., NESTERENKO, V. V., BURASHNIKOV, A., DI DIEGO, J., SAFFITZ, J., & THOMAS, G. P. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00287.x · Cited by 611
Dumaine, R., Towbin, J. A., Brugada, P., Vatta, M., Nesterenko, D. V., Nesterenko, V. V., Brugada, J., Brugada, R., & Antzelevitch, C. (1999) · Circulation Research · doi:10.1161/01.res.85.9.803 · Cited by 601
Shimizu, W., & Antzelevitch, C. (1997) · Circulation · doi:10.1161/01.cir.96.6.2038 · Cited by 524
Cited by
O'Hara, T., Virág, L., Varró, A., & Rudy, Y. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002061 · Cited by 1,196
Self-citationNoninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y. (2004) · Nature Medicine · doi:10.1038/nm1011 · Cited by 646
Self-citationPotse, M., Dube, B., Richer, J., Vinet, A., & Gulrajani, R. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880875 · Cited by 470
Chaste: An Open Source C++ Library for Computational Physiology and Biology
Mirams, G. R., Arthurs, C. J., Bernabeu, M. O., Bordas, R., Cooper, J., Corrias, A., Davit, Y., Dunn, S.-J., Fletcher, A. G., Harvey, D. G., et al. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002970 · Cited by 423
Minimal model for human ventricular action potentials in tissue
Bueno-Orovio, A., Cherry, E. M., & Fenton, F. H. (2008) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2008.03.029 · Cited by 409
Metadata
- Authors
- Gima, K., & Rudy, Y.
- Venue
- Circulation Research
- Published
- 2002-05-03
- Volume
- 90
- Issue
- 8
- Pages
- 889-896
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2107658445
- Cited by
- 396
- References
- 30
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic Current Basis of Electrocardiographic Waveforms: A Model Study. https://app.cochat.ai/papers/10.1161/01.res.0000016960.61087.86
- The paper
- Gima, K., & Rudy, Y. (2002). Ionic Current Basis of Electrocardiographic Waveforms: A Model Study. Circulation Research. https://doi.org/10.1161/01.res.0000016960.61087.86
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.