The DOI matches its Crossref record.
Heme Is a Carbon Monoxide Receptor for Large-Conductance Ca 2+ -Activated K + Channels
Open accessAbstract
Carbon monoxide (CO) is an endogenous paracrine and autocrine gaseous messenger that regulates physiological functions in a wide variety of tissues. CO induces vasodilation by activating arterial smooth muscle large-conductance Ca 2+ -activated potassium (BK Ca ) channels. However, the mechanism by which CO activates BK Ca channels remains unclear. Here, we tested the hypothesis that CO activates BK Ca channels by binding to channel-bound heme, a BK Ca channel inhibitor, and altering the interaction between heme and the conserved heme-binding domain (HBD) of the channel α subunit C terminus. Data obtained using thin-layer chromatography, spectrophotometry, mass spectrometry (MS), and MS-MS indicate that CO modifies the binding of reduced heme to the α subunit HBD. In contrast, CO does not alter the interaction between the HBD and oxidized heme (hemin), to which CO cannot bind. Consistent with these findings, electrophysiological measurements of native and cloned (cbv) cerebral artery smooth muscle BK Ca channels show that CO reverses BK Ca channel inhibition by heme but not by hemin. Site-directed mutagenesis of the cbv HBD from CKACH to CKASR abolished both heme-induced channel inhibition and CO-induced activation. Furthermore, on binding CO, heme switches from being a channel inhibitor to an activator. These findings indicate that reduced heme is a functional CO receptor for BK Ca channels, introduce a unique mechanism by which CO regulates the activity of a target protein, and reveal a novel process by which a gaseous messenger regulates ion channel activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogen sulfide as a gasotransmitter
Gadalla, M. M., & Snyder, S. H. (2010) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.06580.x · Cited by 498
Astrocytes and the regulation of cerebral blood flow
Koehler, R. C., Roman, R. J., & Harder, D. R. (2009) · Trends in Neurosciences · doi:10.1016/j.tins.2008.11.005 · Cited by 444
Carbon monoxide – physiology, detection and controlled release
Heinemann, S. H., Hoshi, T., Westerhausen, M., & Schiller, A. (2014) · Chem. Commun. · doi:10.1039/c3cc49196j · Cited by 388
Nakahira, K., Kim, H. P., Geng, X. H., Nakao, A., Wang, X., Murase, N., Drain, P. F., Wang, X., Sasidhar, M., Nabel, E. G., et al. (2006) · The Journal of Experimental Medicine · doi:10.1084/jem.20060845 · Cited by 358
Smooth Muscle Ion Channels and Regulation of Vascular Tone in Resistance Arteries and Arterioles
Tykocki, N. R., Boerman, E. M., & Jackson, W. F. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160011 · Cited by 335
Metadata
- Authors
- Jaggar, J. H., Li, A., Parfenova, H., Liu, J., Umstot, E. S., Dopico, A. M., & Leffler, C. W.
- Venue
- Circulation Research
- Published
- 2005-10-14
- Volume
- 97
- Issue
- 8
- Pages
- 805-812
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2109042906
- Cited by
- 217
- References
- 0
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heme Is a Carbon Monoxide Receptor for Large-Conductance Ca 2+ -Activated K + Channels. https://app.cochat.ai/papers/10.1161/01.res.0000186180.47148.7b
- The paper
- Jaggar, J. H., Li, A., Parfenova, H., Liu, J., Umstot, E. S., Dopico, A. M., & Leffler, C. W. (2005). Heme Is a Carbon Monoxide Receptor for Large-Conductance Ca 2+ -Activated K + Channels. Circulation Research. https://doi.org/10.1161/01.res.0000186180.47148.7b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.