The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Equations for Measuring Blood Flow by External Monitoring of Radioisotopes
Open accessAbstract
It is possible by external monitoring alone to measure blood flow per unit volume through any vascular bed accessible to external monitoring of the radioactive tracer if the tracer input function or if the quantity of tracer entering the system is known. The methods proposed exploit the fact that the mean transit time through the system is the flow per unit volume of distribution of tracer. The equations are free of assumptions that require solutions as exponentials or any other specified frequency function of transit times. If the input function is known, measurement of the concentration of tracer in blood leaving the part sensed by the external detector, combined with external detection of radioactivity, can lead to measurement of absolute blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
Self-citationMeasurement of regional circulation by the local clearance of radioactive sodium
Kety, S. S. (1949) · American Heart Journal · doi:10.1016/0002-8703(49)90845-5 · Cited by 530
Zierler, K. L. (1961) · Journal of Clinical Investigation · doi:10.1172/jci104437 · Cited by 401
Self-citationROSS, R. S., UEDA, K., LICHTLEN, P. R., REES, J. R., Redden, R., & Kaelber, C. (1964) · Circulation Research · doi:10.1161/01.res.15.1.28 · Cited by 250
Lewis, B. M., Sokoloff, L., Wechsler, R. L., Wentz, W. B., & Kety, S. S. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104087 · Cited by 57
Cited by
Brain Metabolism during Fasting*
Owen, O. E., Morgan, A. P., Kemp, H. G., Sullivan, J. M., Herrera, M. G., & Cahill, G. F. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105650 · Cited by 1,646
Physiologic basis for assessing critical coronary stenosis
Gould, K. L., Lipscomb, K., & Hamilton, G. W. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90743-7 · Cited by 1,532
The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time
GRUBB, R. L., RAICHLE, M. E., EICHLING, J. O., & TER-POGOSSIAN, M. M. (1974) · Stroke · doi:10.1161/01.str.5.5.630 · Cited by 1,044
Kernel methods in system identification, machine learning and function estimation: A survey
Pillonetto, G., Dinuzzo, F., Chen, T., De Nicolao, G., & Ljung, L. (2014) · Automatica · doi:10.1016/j.automatica.2014.01.001 · Cited by 741
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423
Metadata
- Authors
- ZIERLER, K. L.
- Venue
- Circulation Research
- Published
- 1965-04
- Volume
- 16
- Issue
- 4
- Pages
- 309-321
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2071233005
- Cited by
- 786
- References
- 5
- FWCI
- 35.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equations for Measuring Blood Flow by External Monitoring of Radioisotopes. https://app.cochat.ai/papers/10.1161/01.res.16.4.309
- The paper
- ZIERLER, K. L. (1965). Equations for Measuring Blood Flow by External Monitoring of Radioisotopes. Circulation Research. https://doi.org/10.1161/01.res.16.4.309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.