The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Improved Assay Methods for Renin "Concentration" and "Activity" in Human Plasma: Methods Using Selective Denaturation Of Renin Substrate
Abstract
Simplified methods are described for the measurement of human plasma renin "concentration" (PRC) and "activity" (PRA) based on the denaturation of renin substrate in which separation and concentration steps are avoided and recovery of renin is complete. In the PRA method effective inhibition of angiotensinase is achieved by warming plasma at pH 4.5 with EDTA followed by dialysis to pH 7.5. Neither renin nor renin substrate is affected by this treatment. In the PRC method, renin substrate is selectively denatured by warming at pH 3.3. After dialysis to pH 7.5 and addition of a standard substrate prepared from nephrectomized sheep, incubation results in a linear increase of pressor material which is assayed without extraction on rat blood pressure against synthetic angiotensin. Specificity is established by nephrectomy and immunological studies. The linear relationship between plasma renin concentration and reaction rate contrasted with the nonlinearity observed with renal renin. The systems are suitable for routine diagnostic use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colowick, S. P., Joshi, M. D., Jagannathan, & KAPLAN, N. O. (1966) · Cited by 26,137
THE PREPARATION AND FUNCTION OF THE HYPERTENSIN-CONVERTING ENZYME
Skeggs, L. T., Kahn, J. R., & Shumway, N. P. (1956) · The Journal of Experimental Medicine · doi:10.1084/jem.103.3.295 · Cited by 1,032
THE BIURET REACTION IN THE DETERMINATION OF SERUM PROTEINS
Robinson, H. W., & Hogden, C. G. (1940) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)73134-7 · Cited by 796
Measurement of Renin Activity in Human Plasma
PICKENS, P. T., BUMPUS, F. M., LLOYD, A. M., SMEBY, R. R., & PAGE, L. H. (1965) · Circulation Research · doi:10.1161/01.res.17.5.438 · Cited by 246
The Quantitative Determination of Renin in the Plasma of Patients with Arterial Hypertension
Helmer, O. M., Judson, W. E., & Sanders, R. M. (1963) · Circulation · doi:10.1161/01.cir.27.6.1050 · Cited by 117
Cited by
The renin system: Variations in man measured by radioimmunoassay or bioassay
Sealey, J. E., Gerten-Banes, J., & Laragh, J. H. (1972) · Kidney International · doi:10.1038/ki.1972.34 · Cited by 382
Davis, G. C., Gibson, K. J., Casley, D., & Brown, M. A. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001310 · Cited by 13
Metadata
- Authors
- SKINNER, S. L.
- Venue
- Circulation Research
- Published
- 1967-04
- Volume
- 20
- Issue
- 4
- Pages
- 391-402
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2127054656
- Cited by
- 401
- References
- 5
- FWCI
- 21.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Assay Methods for Renin "Concentration" and "Activity" in Human Plasma: Methods Using Selective Denaturation Of Renin Substrate. https://app.cochat.ai/papers/10.1161/01.res.20.4.391
- The paper
- SKINNER, S. L. (1967). Improved Assay Methods for Renin "Concentration" and "Activity" in Human Plasma: Methods Using Selective Denaturation Of Renin Substrate. Circulation Research. https://doi.org/10.1161/01.res.20.4.391
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.