Human Cardiovascular Adjustments to Rapid Changes in Skin Temperature during Exercise
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
In 11 normal men, central circulatory responses were measured while skin temperature was changed in a square-wave pattern during uninterrupted exercise (26% to 64% maximal oxygen consumption). Skin temperature was changed at 30-minute intervals, beginning at 32°C. On raising it to 38.2°C at low oxygen consumption (V · o 2 ), cardiac output increased 2.5 liters/min, and central blood volume, aortic mean pressure, and stroke volume fell (7%, 7%, and 11%, respectively). Right atrial mean pressure fell 2.2 and 2.3 mm Hg during control and heating periods, respectively. All variables returned to control levels when skin temperature was reduced toward 26.9°C. Raising it to 40°C reproduced these changes with a more clear-cut drop in right atrial mean pressure. Results indicated reduced peripheral venous tone and cutaneous pooling of blood during heating and rapid reversal on cooling. On raising skin temperature to 38.7°C at high V · o 2 , cardiac output increased 19% (3.1 liters/min), stroke volume decreased 14%, and central blood volume rose slightly. Aortic mean pressure fell during the control period and was maintained or rose during heating periods. On cooling, central blood volume and stroke volume rose, cardiac output remained elevated, and aortic mean pressure fell. Increases in cardiac output during heating were related to skin temperature and not to V · o 2 or body temperature. At high V · o 2 , circulatory adjustments favor metabolic rather than thermoregulatory demands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal Oxygen Intake as an Objective Measure of Cardio-Respiratory Performance
Taylor, H. L., Buskirk, E., & Henschel, A. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.1.73 · Cited by 1,342 · cited 1×
“(5) or multistage exercise on a treadmill to exhaustion (6).”
BackgroundRowell, L. B., Marx, H. J., Bruce, R. A., Conn, R. D., & Kusumi, F. (1966) · Journal of Clinical Investigation · doi:10.1172/jci105484 · Cited by 279 · cited 5×
“Similar responses were observed in a previous study (8).”
BackgroundMethodResultInfluentialSelf-citationMyocardial ischemia after maximal exercise in healthy men
Doan, A. E., Peterson, D. R., Blackmon, J. R., & Bruce, R. A. (1965) · American Heart Journal · doi:10.1016/0002-8703(65)90211-5 · Cited by 266
ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A. (1968) · Circulation · doi:10.1161/01.cir.37.6.954 · Cited by 257 · cited 1×
“Right atrial mean pressure was measured with a Statham P23Db transducer and Honeywell 131-2C carrier amplifier and a previously described (9) electrical averaging circuit (critically damped, 0.”
MethodSelf-citationThe Influence of Anoxia on Lactate Utilization in Man after Prolonged Muscnlar Work
STRÖM, G. (1949) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1949.tb00589.x · Cited by 247
Splanchnic blood flow and metabolism in heat-stressed man.
Rowell, L. B., Brengelmann, G. L., Blackmon, J. R., Twiss, R. D., & Kusumi, F. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.24.4.475 · Cited by 208 · cited 1×
“There are data suggesting that muscle blood flow may even be reduced during exercise in a hot environment since arterial lactate concentrations tended to be higher than normal (7, 14) while oxygen uptake was maintained at (7, 8) or slightly below control values (14, 15).”
BackgroundSelf-citationHOLMGREN, A. (1956) · PubMed · Cited by 207
Reaction in man of resistance and capacity vessels in forearm and hand to leg exercise.
Bevegård, B. S., & Shepherd, J. T. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.123 · Cited by 206 · cited 3×
“Raising skin temperature abolished the level of peripheral venoconstriction which is normally increased in proportion to the severity of exercise (3, 4).”
BackgroundMethodHepatic clearance of indocyanine green in man under thermal and exercise stresses
Rowell, L. B., Blackmon, J. R., Martin, R. H., Mazzarella, J. A., & Bruce, R. A. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.3.384 · Cited by 185 · cited 5×
“There are data suggesting that muscle blood flow may even be reduced during exercise in a hot environment since arterial lactate concentrations tended to be higher than normal (7, 14) while oxygen uptake was maintained at (7, 8) or slightly below control values (14, 15).”
BackgroundMethodInfluentialSelf-citationEffects of Environmental Heat Stress and Exercise on Renal Blood Flow and Filtration Rate
Radigan, L. R., & Robinson, S. (1949) · Journal of Applied Physiology · doi:10.1152/jappl.1949.2.4.185 · Cited by 136 · cited 2×
“During heating, renal (16) and splanchnic blood flow (7) fall below levels normally found at the same intensity of exercise in cool environments.”
BackgroundRoddie, I. C., Shepherd, J. T., & Whelan, R. F. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005656 · Cited by 136 · cited 2×
“All data, except cardiac output, which was measured by rectangulation from the original records (10), was processed by hand from tape-recorded data replayed at very slow recorder paper speeds.”
BackgroundMethodCirculatory and metabolic reactions to work in heat
Williams, C. G., Bredell, G. A. G., Wyndham, C. H., Strydom, N. B., Morrison, J. F., Peter, J., Fleming, P. W., & Ward, J. S. (1962) · Journal of Applied Physiology · doi:10.1152/jappl.1962.17.4.625 · Cited by 125 · cited 1×
“There are data suggesting that muscle blood flow may even be reduced during exercise in a hot environment since arterial lactate concentrations tended to be higher than normal (7, 14) while oxygen uptake was maintained at (7, 8) or slightly below control values (14, 15).”
BackgroundWood, J. E., & Eckstein, J. W. (1958) · Journal of Clinical Investigation · doi:10.1172/jci103583 · Cited by 118 · cited 1×
“There are also previous reports of venoconstriction with lowering of skin temperature (18, 20).”
BackgroundEkelund, L. G., & Holmgren, A. (1964) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1964.tb03971.x · Cited by 92
Responses of the Superficial Limb Veins of the Dog to Changes in Temperature
Webb‐Peploe, M. M., & Shepherd, J. T. (1968) · Circulation Research · doi:10.1161/01.res.22.6.737 · Cited by 56 · cited 2×
“There are also previous reports of venoconstriction with lowering of skin temperature (18, 20).”
BackgroundUse of sweating rate to predict other physiological responses to heat.
Kraning, K. K., Belding, H. S., & Hertig, B. A. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.111 · Cited by 25 · cited 4×
“? Possible explanations of the reversal of aortic mean pressure responses at the high oxygen uptake, that is, rise with heating and initial fall with cooling, are as follows: (1) The increase in cardiac output was unaccompanied by any further net vasodilatation so that total peripheral resistance remained constant fro…”
BackgroundInfluentialSelf-citation
Cited by
The Effects of Climate Change on Cardiac Health
De Blois, J., Kjellstrom, T., Agewall, S., Ezekowitz, J. A., Armstrong, P. W., & Atar, D. (2015) · Cardiology · doi:10.1159/000398787 · Cited by 1,697
Influence of body temperature on the development of fatigue during prolonged exercise in the heat
González-Alonso, J., Teller, C., Andersen, S. L., Jensen, F. B., Hyldig, T., & Nielsen, B. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1032 · Cited by 1,129
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
José, G.-A., Mora-Rodríguez, R., Below, P. R., & Coyle, E. F. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1229 · Cited by 390
Metadata
- Authors
- ROWELL, L. B., MURRAY, J. A., BRENGELMANN, G. L., & KRANING, K. K.
- Venue
- Circulation Research
- Published
- 1969-05
- Volume
- 24
- Issue
- 5
- Pages
- 711-724
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2159029194
- Cited by
- 176
- References
- 16
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.