The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in Man
Abstract
Blood pressures were recorded simultaneously from the aortic arch and radial artery using two manometric systems with identical static and dynamic sensitivities. Measurements were made in four normal young men at rest and upright exercise requiring 29, 49, 78, and 100% of maximal oxygen uptake. Average radial arterial pressure rose from 133/66 mm Hg at rest to 236/58 mm Hg at maximal exercise. At the same time, average aortic pressures were 112/68 and 154/70 mm Hg, respectively. From rest to maximal exercise, pulse pressures at central and peripheral sites increased by factors of 1.95 and 2.60, respectively. Inducing reactive hyperemia in the arm abolished peripheral amplification. This amplification also diminished with time during prolonged heavy exercise. Mean pressures were nearly identical at the two sites at any oxygen uptake; mean pressures rose from 87 to 104 mm Hg from mild to maximal exercise. We conclude that estimates of stress on aortic and cerebral vessel walls and central baroreceptors would be grossly overestimated by use of peripheral pulse pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burton, A. C. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.3.437 · Cited by 333
Cited by
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Gobel, F. L., Norstrom, L. A., Nelson, R. R., Jorgensen, C. R., & Wang, Y. (1978) · Circulation · doi:10.1161/01.cir.57.3.549 · Cited by 866
Metadata
- Authors
- ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A.
- Venue
- Circulation
- Published
- 1968-06
- Volume
- 37
- Issue
- 6
- Pages
- 954-964
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2127334473
- Cited by
- 257
- References
- 1
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in Man. https://app.cochat.ai/papers/10.1161/01.cir.37.6.954
- The paper
- ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A. (1968). Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in Man. Circulation. https://doi.org/10.1161/01.cir.37.6.954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.