The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs
Open accessAbstract
Total and regional coronary blood flow were measured in dogs by left atrial injection of carbonized microspheres labeled with different radioactive isotopes (mean diameter 14 to 61µ). Simultaneously blood was collected at 20 ml/min from a catheter tied into a peripheral artery. The ratios of flow to radioactivity in myocardium and arterial blood should be equal if microspheres are well mixed in the aortic root and are distributed regionally in proportion to flow. This was proved in seven right heart by-pass experiments where coronary venous drainage was measured directly. Also, less than 0.1% of total myocardial radioactivity appeared in coronary venous blood, even with hypoxemia and small microspheres. Total coronary flow in seven conscious dogs averaged 95 to 150 ml/min/100 g heart; and flow to the left ventricle was 111 to 169 ml/100 g. Although not validated independently, there was evidence that values for flow to each ventricle, the atria and the septum were correct. The radioactivity per gram of left ventricular subendocardial muscle was 2.5 times that of subepicardial muscle using microspheres 51 to 61µ in diameter, but the ratios were 1.4 and 1.3 using microspheres of mean diameters 20 to 23µ and 14µ, respectively. It is unlikely that any of these microspheres measure blood flow to small portions of the ventricle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RUDOLPH, A. M., & HEYMANN, M. A. (1967) · Circulation Research · doi:10.1161/01.res.21.2.163 · Cited by 1,316
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Use of radioactive microspheres to assess distribution of cardiac output in rabbits
Neutze, J., Wyler, F., & Rudolph, A. (1968) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1968.215.2.486 · Cited by 286
The Relation of Cardiac Effort to Myocardial Oxygen Consumption and Coronary Flow
KATZ, L. N., & FEINBERG, H. (1958) · Circulation Research · doi:10.1161/01.res.6.5.656 · Cited by 259
Nonuniform distribution of blood flow and gradients of oxygen tension within the heart
Kirk, E. S., & Honig, C. R. (1964) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1964.207.3.661 · Cited by 250
The vascular supply of the left ventricular wall
Estes, E. H., Entman, M. L., Dixon, H. B., & Hackel, D. B. (1966) · American Heart Journal · doi:10.1016/0002-8703(66)90657-0 · Cited by 165
MEASUREMENT OF CORONARY BLOOD FLOW BY THE NITROUS OXIDE METHOD
Eckenhoff, J. E., Hafkenschiel, J. H., Harmel, M. H., Goodale, W. T., Lubin, M., Bing, R. J., & Kety, S. S. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.152.2.356 · Cited by 152
Berglund, E., Borst, H. G., Duff, F. A., & SCHREINER, G. L. (1958) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1958.tb01551.x · Cited by 131
Cited by
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
Self-citationPrzyklenk, K., Bauer, B., Ovize, M., Kloner, R. A., & Whittaker, P. (1993) · Circulation · doi:10.1161/01.cir.87.3.893 · Cited by 1,379
Some sources of error in measuring regional blood flow with radioactive microspheres.
Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I., Archie, J. P., & Fixler, D. E. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.598 · Cited by 1,132
Self-citationExperimental Subendocardial Ischemia in Dogs with Normal Coronary Arteries
BUCKBERG, G. D., FIXLER, D. E., ARCHIE, J. P., & HOFFMAN, J. I. E. (1972) · Circulation Research · doi:10.1161/01.res.30.1.67 · Cited by 845
Self-citationKim, R. J., Chen, E.-L., Lima, J. A. C., & Judd, R. M. (1996) · Circulation · doi:10.1161/01.cir.94.12.3318 · Cited by 662
Metadata
- Authors
- DOMENECH, R. J., HOFFMAN, J. I., NOBLE, M. I., SAUNDERS, K. B., HENSON, J. R., & SUBIJANTO, S.
- Venue
- Circulation Research
- Published
- 1969-11
- Volume
- 25
- Issue
- 5
- Pages
- 581-596
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2117730908
- Cited by
- 670
- References
- 8
- FWCI
- 21.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs. https://app.cochat.ai/papers/10.1161/01.res.25.5.581
- The paper
- DOMENECH, R. J., HOFFMAN, J. I., NOBLE, M. I., SAUNDERS, K. B., HENSON, J. R., & SUBIJANTO, S. (1969). Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs. Circulation Research. https://doi.org/10.1161/01.res.25.5.581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.