The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The Circulation of the Fetus in Utero: Methods For Studying Distribution of Blood Flow, Cardiac Output And Organ Blood Flow
Abstract
Techniques are described for insertion of vinyl catheters into the umbilical and limb vessels of the fetus of the sheep or the goat through small uterine incisions, with the ewes under spinal analgesia. The catheters are exteriorized and the fetus can be studied in its normal intrauterine environment. During constant infusion of antipyrine into a fetal limb vein, placental arteriovenous difference of antipyrine was measured, and fetal umbilical blood flow was calculated by the Fick method. "Carbonized" microspheres (50-µ diameter) labeled with various nuclides were injected into different venous sites in the fetus. The distribution pattern of the microspheres was used to determine the relative distribution of blood flow. Experimental evidence is provided that (1) there is no significant recirculation of microspheres, (2) the distribution of spheres is proportional to flow, and (3) circulatory physiology is not altered by injection of spheres. Quantitative data on the distribution of umbilical venous and superior and inferior vena caval return were obtained. It was possible to determine the actual blood flow to each of the fetal organs by relating the proportions of nuclide in each organ to that in the placenta. Total cardiac output was then calculable, taking into consideration the hemodynamic arrangement of the fetal circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of the pulmonary vasculature to hypoxia and H+ ion concentration changes.
Rudolph, A. M., & Yuan, S. (1966) · Journal of Clinical Investigation · doi:10.1172/jci105355 · Cited by 551
Self-citation(1947) · Archives of Disease in Childhood · doi:10.1136/adc.22.111.183 · Cited by 333
Fractionation of the Cardiac Output of Rats with Isotopic Potassium
SAPIRSTEIN, L. A. (1956) · Circulation Research · doi:10.1161/01.res.4.6.689 · Cited by 208
SIMULTANEOUS MEASUREMENT OF UTERINE AND UMBILICAL BLOOD FLOWS AND OXYGEN UPTAKES
Meschia, G., Cotter, J. R., Makowski, E. L., & Barron, D. H. (1967) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1967.sp001877 · Cited by 193
Cited by
Xanthine oxidase as a source of free radical damage in myocardial ischemia
CHAMBERS, D., PARKS, D., PATTERSON, G., ROY, R., MCCORD, J., YOSHIDA, S., PARMLEY, L., & DOWNEY, J. (1985) · Journal of Molecular and Cellular Cardiology · doi:10.1016/s0022-2828(85)80017-1 · Cited by 672
Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
Glenny, R. W., Bernard, S., & Brinkley, M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2585 · Cited by 365
Viires, N., Sillye, G., Aubier, M., Rassidakis, A., & Roussos, C. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111065 · Cited by 185
Prsa, M., Sun, L., van Amerom, J., Yoo, S.-J., Grosse-Wortmann, L., Jaeggi, E., Macgowan, C., & Seed, M. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001859 · Cited by 168
Distribution of respiratory muscle and organ blood flow during endotoxic shock in dogs
Hussain, S. N., & Roussos, C. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.6.1802 · Cited by 115
Metadata
- Authors
- RUDOLPH, A. M., & HEYMANN, M. A.
- Venue
- Circulation Research
- Published
- 1967-08
- Volume
- 21
- Issue
- 2
- Pages
- 163-184
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2132924014
- Cited by
- 1,316
- References
- 4
- FWCI
- 54.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Circulation of the Fetus in Utero: Methods For Studying Distribution of Blood Flow, Cardiac Output And Organ Blood Flow. https://app.cochat.ai/papers/10.1161/01.res.21.2.163
- The paper
- RUDOLPH, A. M., & HEYMANN, M. A. (1967). The Circulation of the Fetus in Utero: Methods For Studying Distribution of Blood Flow, Cardiac Output And Organ Blood Flow. Circulation Research. https://doi.org/10.1161/01.res.21.2.163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.