The DOI matches its Crossref record.
Pressure and Flow Generated by the Left Ventricle against Different Impedances
Abstract
To study selective changes in capacitive and resistive load under constant left atrial filling pressure, isolated cat hearts were loaded with a hydraulic model simulating the input impedance of the systemic arteries. The model was constructed so that resistive (peripheral resistance) and capacitive (total arterial compliance) characteristics could be changed independently. Aortic and left ventricular pressure and aortic flow, as generated by the left ventricle against the different impedances, were measured. An increase in resistance resulted in an increase in systolic, diastolic, and mean aortic pressure. A decrease in capacitance caused a small increase in systolic pressure and a decrease in diastolic and mean aortic pressure. Mean left ventricular pressure increased when resistance increased or capacitance decreased. Both peak flow and mean flow decreased when resistance increased or capacitance decreased. We attempted to explain these observations by the concept of source impedance. This concept had been, until now, incorrectly approached, because the nonlinearity arising from the aortic valves had been neglected. The correct computations met with difficulties, but it was shown that the isolated heart, with constant atrial filling pressure, behaved as neither a flow source nor a pressure source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?: The Framingham Heart Study
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,759
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Vascular Smooth Muscle Cells and Arterial Stiffening: Relevance in Development, Aging, and Disease
Lacolley, P., Regnault, V., Segers, P., & Laurent, S. (2017) · Physiological Reviews · doi:10.1152/physrev.00003.2017 · Cited by 734
Optimal arterial resistance for the maximal stroke work studied in isolated canine left ventricle.
Sunagawa, K., Maughan, W. L., & Sagawa, K. (1985) · Circulation Research · doi:10.1161/01.res.56.4.586 · Cited by 474
Coronary circulation in dogs with an experimental decrease in aortic compliance
Watanabe, H., Ohtsuka, S., Kakihana, M., & Sugishita, Y. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90330-4 · Cited by 278
Metadata
- Authors
- ELZINGA, G., & WESTERHOF, N.
- Venue
- Circulation Research
- Published
- 1973-02
- Volume
- 32
- Issue
- 2
- Pages
- 178-186
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2030110174
- Cited by
- 270
- References
- 0
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pressure and Flow Generated by the Left Ventricle against Different Impedances. https://app.cochat.ai/papers/10.1161/01.res.32.2.178
- The paper
- ELZINGA, G., & WESTERHOF, N. (1973). Pressure and Flow Generated by the Left Ventricle against Different Impedances. Circulation Research. https://doi.org/10.1161/01.res.32.2.178
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.