The DOI matches its Crossref record.
Transcapillary Escape Rate of Albumin and Plasma Volume in Essential Hypertension
Open accessAbstract
The transcapillary escape rate of albumin, the fraction of intravascular mass of albumin that passes to the extravascular space per unit time, was determined from the disappearance of intravenously injected 131 I-labeled human serum albumin during the first 60 minutes after the injection in 10 normotensive and 18 hypertensive male subjects. The investigation was preceded by at least 12 hours of fasting and 30 minutes of rest in the supine position. The transcapillary escape rate of albumin was significantly increased in the hypertensive group: it averaged 7.6±1.2 (SD) %/hour compared with 5.6±1.1%/hour in the normotensive group ( P <0.001). Similar results were obtained for the outflux of albumin, the mass of intravascular albumin that passes to the extravascular space per unit time, when identical intravascular albumin masses were compared ( P <0.001). A highly significant correlation between the transcapillary escape rate of albumin and blood pressure was found in the hypertensive group ( P <0.001). Therefore, the increased transcapillary escape rate and the outflux of albumin probably reflected an increase in arteriolar and capillary permeability to albumin. This increase was probably due to the high intra-arterial pressure, which induces constriction in some arteries and dilatation in others and thus allows the high intraluminal pressure to be transmitted distally with distention of the small vessel walls. Finally, a significant reduction in plasma volume was found in the hypertensive subjects ( P <0.05).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Cardiovascular Health Study: design and rationale.
Fried, L. P., Borhani, N. O., Enright, P., Furberg, C. D., Gardin, J. M., Kronmal, R. A., Kuller, L. H., Manolio, T. A., Mittelmark, M. B., Newman, A., et al. (1991) · Annals of Epidemiology · doi:10.1016/1047-2797(91)90005-w · Cited by 3,652
Hyperfiltration in remnant nephrons: a potentially adverse response to renal ablation
Hostetter, T. H., Olson, J. L., Rennke, H. G., Venkatachalam, M. A., & Brenner, B. M. (1981) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1981.241.1.f85 · Cited by 1,680
INCREASED VASCULAR PERMEABILITY: A MAJOR CAUSE OF HYPOALBUMINAEMIA IN DISEASE AND INJURY
Fleck, A., Hawker, F., Wallace, P. I., Raines, G., Trotter, J., Ledingham, I. M., & Calman, K. C. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91447-3 · Cited by 898
Review article: albumin as a drug—biological effects of albumin unrelated to oncotic pressure
Evans, T. W. (2002) · Alimentary Pharmacology & Therapeutics · doi:10.1046/j.1365-2036.16.s5.2.x · Cited by 409
INCREASED URINARY ALBUMIN-EXCRETION RATE IN BENIGN ESSENTIAL HYPERTENSION
Parving, H.-H., Mogensen, C. E., Jensen, H. Æ., & Evrin, P.-E. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91002-2 · Cited by 409
Self-citation
Metadata
- Authors
- PARVING, H.-H., & GYNTELBERG, F.
- Venue
- Circulation Research
- Published
- 1973-05
- Volume
- 32
- Issue
- 5
- Pages
- 643-652
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2130260569
- Cited by
- 235
- References
- 0
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcapillary Escape Rate of Albumin and Plasma Volume in Essential Hypertension. https://app.cochat.ai/papers/10.1161/01.res.32.5.643
- The paper
- PARVING, H.-H., & GYNTELBERG, F. (1973). Transcapillary Escape Rate of Albumin and Plasma Volume in Essential Hypertension. Circulation Research. https://doi.org/10.1161/01.res.32.5.643
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.