Total and Regional Myocardial Blood Flow Measurements with 25µ, 15µ, 9µ, and Filtered 1-10µ Diameter Microspheres and Antipyrine in Dogs and Sheep
Open accessThe DOI matches its Crossref record.
Abstract
The accuracy of regional myocardial blood flow measurements made with microspheres of different sizes is uncertain. Therefore, we simultaneously injected radioactive microspheres of different sizes into the left atria of dogs and sheep; the microsphere diameters were 25µ, 15µ, 9µ, 1-l0µ, and filtered 1-10µ (most > 7µ). Antipyrine was sometimes simultaneously infused for 15-60 seconds. Myocardial blood flow was altered by hemorrhage, tachycardia, supravalvar aortic constriction, or infusion of methoxamine or adenosine triphosphate; left coronary artery branches were occluded on two occasions. Sometimes the percent of untrapped microspheres was estimated. All sizes of microspheres measured similar total myocardial blood flows when the percent of untrapped microspheres was known. All indicators were distributed identically to the right and left ventricular free walls and septum; ischemic areas had a 1% excess of antipyrine. With any pair of microspheres, the larger had a subendocardial excess except for 25µ microspheres, which were in excess compared with 15µ microspheres in the higher flow layer whether it was subendocardial or subepicardial. The greatest difference for any pair of microspheres was 10.53% of flow in a layer. Antipyrine did not define which size of microspheres measured true regional blood flow, since many previously unemphasized limitations were discovered. Nevertheless, we believe that microspheres 9µ in diameter are probably the best for measuring regional myocardial blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
Self-citationRegulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
(1999) · PubMed · Cited by 230
Safety of prolonged aortic clamping with blood cardioplegia
Rosenkranz, E. R., Okamoto, F., Buckberg, G. D., Robertson, J. M., Vinten-Johansen, J., & Bugyi, H. I. (1986) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36059-3 · Cited by 225
Self-citationBlood flow distributions by microsphere deposition methods
Prinzen, F. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00252-7 · Cited by 182
Metadata
- Authors
- UTLEY, J., CARLSON, E. L., HOFFMAN, J. I. E., MARTINEZ, H. M., & BUCKBERG, G. D.
- Venue
- Circulation Research
- Published
- 1974-03
- Volume
- 34
- Issue
- 3
- Pages
- 391-405
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2131896058
- Cited by
- 210
- References
- 0
- FWCI
- 30.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.