Vascular endothelium-leukocyte interaction; sticking shear force in venules.
The DOI matches its Crossref record.
Abstract
To determine the shear force acting on a white blood cell sticking to the endothelium of a blood vessel, the flow field about a single white blood cell in a venule was determined by hign-speed motion picture photomicrography. The force acting on the white blood cell was then calculated according to the principles of fluid mechanics. In this paper, the calculation was made using an experimentally determined dimensionless shear force coefficient obtained from a kinematically and dynamically similar model. The large physical model of the hemodynamic system could be easily instrumented, and the shear force acting on the model cell and the flow field around it were measured. The data were then used to calculate a shear force coefficient. On the basis of dynamic similarity, this shear force coefficient was applied to the white blood cell in the venule. The shear force coefficient was strongly influenced by the hematocrit, so in vivo hematocrits were measured from electron micrographs. It was found that in the venules of the rabbit omentum a white blood cell sticking to the endothelial wall was subjected to a shear force in the range of 4 times 10--5 dynes to 234 times 10--5 dynes; the exact value depended on the size and motion of the white blood cell, the size of the blood vessel, the velocity of the blood flow, and the local hematocrit, which varied between 20% and 40% in venules of about 40 mum in diameter. The contact area between the white blood cell and the endothelial cell was estimated, and the shear stress was found to range between 50 dynes/cm-2 and 1060 dynes/cm-2. The normal stress of interaction between the white blood cell and the endothelium had a maximum value that was of the same order of magnitude as the shear stress. The accumulated relative error of the experimental procedure was about 49%. The instantaneous shear force was a random function of time because of random fluctuations of the hematocrit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laminar Shear Stress: Mechanisms by Which Endothelial Cells Transduce an Atheroprotective Force
Traub, O., & Berk, B. C. (1998) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.18.5.677 · Cited by 1,085
Smith, C. W., Rothlein, R., Hughes, B. J., Mariscalco, M. M., Rudloff, H. E., Schmalstieg, F. C., & Anderson, D. C. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113788 · Cited by 599
Leukocytes and the Risk of Ischemic Diseases
Ernst, E. (1987) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1987.03390170074031 · Cited by 541
Role of leukocytes in response to acute myocardial ischemia and reflow in dogs
Engler, R. L., Dahlgren, M. D., Morris, D. D., Peterson, M. A., & Schmid-Schonbein, G. W. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.2.h314 · Cited by 507
Passive mechanical properties of human leukocytes
Schmid-Schönbein, G. W., Sung, K. L., Tözeren, H., Skalak, R., & Chien, S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84726-1 · Cited by 417
In vivo measurements of “apparent viscosity” and microvessel hematocrit in the mesentery of the cat
Lipowsky, H. H., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90050-3 · Cited by 398
Expression of ICAM-1 and VCAM-1 and Monocyte Adherence in Arteries Exposed to Altered Shear Stress
Walpola, P. L., Gotlieb, A. I., Cybulsky, M. I., & Langille, B. L. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.15.1.2 · Cited by 389
The interaction of leukocytes and erythrocytes in capillary and postcapillary vessels
Schmid-Schönbein, G. W., Usami, S., Skalak, R., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90083-7 · Cited by 379
Effect of flow on polymorphonuclear leukocyte/endothelial cell adhesion
Lawrence, M., McIntire, L., & Eskin, S. (1987) · Blood · doi:10.1182/blood.v70.5.1284.1284 · Cited by 373
Effect of venous shear stress on CD18-mediated neutrophil adhesion to cultured endothelium
Lawrence, M., Smith, C., Eskin, S., & McIntire, L. (1990) · Blood · doi:10.1182/blood.v75.1.227.227 · Cited by 359
Leukocyte-endothelium adhesion: Microhemodynamics in mesentery of the cat
House, S. D., & Lipowsky, H. H. (1987) · Microvascular Research · doi:10.1016/0026-2862(87)90068-9 · Cited by 334
A dynamical model for receptor-mediated cell adhesion to surfaces
Hammer, D. A., & Lauffenburger, D. A. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83236-8 · Cited by 258
Ley, K., & Gaehtgens, P. (1991) · Circulation Research · doi:10.1161/01.res.69.4.1034 · Cited by 258
Inflammatory responses to ischemia, and reperfusion in skeletal muscle
Gute, D. C., Ishida, T., Yarimizu, K., & Korthius, R. J. (1998) · Molecular and Cellular Biochemistry · doi:10.1023/a:1006832207864 · Cited by 252
Microfluidic Models of Vascular Functions
Wong, K. H. K., Chan, J. M., Kamm, R. D., & Tien, J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150052 · Cited by 247
“Dynamically similar systems, scaled using principles of continuum mechanics based on the Reynolds number (Re = VD/υ, where V is a characteristic flow velocity, D the vessel diameter, and υ the kinematic viscosity of blood) and Womersley number [α = (D/2) √ ω/υ ], where ω is a characteristic frequency of flow unsteadin…”
BackgroundMethodGiavazzi, R., Foppolo, M., Dossi, R., & Remuzzi, A. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116928 · Cited by 218
Ritter, L. S., Orozco, J. A., Coull, B. M., & McDonagh, P. F. (2000) · Stroke · doi:10.1161/01.str.31.5.1153 · Cited by 197
Organ-preference of metastasis: The role of endothelial cell adhesion molecules
Pauli, B. U., Augustin-Voss, H. G., El-Sabban, M. E., Johnson, R. C., & Hammer, D. A. (1990) · CANCER AND METASTASIS REVIEW · doi:10.1007/bf00046359 · Cited by 197
Particle Diameter Influences Adhesion under Flow
Patil, V. R. S., Campbell, C. J., Yun, Y. H., Slack, S. M., & Goetz, D. J. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76144-9 · Cited by 181
“…et al., 1995; Goldsmith and Turitto, 1986; Chien, 1982]); and 2) the blood vessels are of finite size, and the ratio of vessel diameter to particle diameter can affect the drag force on a particle near the wall (Schmid-Schoenbein et al., 1975; House and Lipowsky, 1988; Chapman and Cokelet, 1998).”
BackgroundGaver, D. P., & Kute, S. M. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77562-9 · Cited by 171
“However, in all cases these results are comparable to predictions made by Fung (1984), based upon the model studies by Schmid-Schoenbein et al. (1975).”
ResultReceptor-mediated adhesion phenomena. Model studies with the Radical-Flow Detachment Assay
Cozens-Roberts, C., Quinn, J. A., & Lauffenberger, D. A. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82357-2 · Cited by 169
Metadata
- Authors
- Schmid-Schoenbein, G. W., Fung, Y. C., & Zweifach, B. W.
- Venue
- Circulation Research
- Published
- 1975-01
- Volume
- 36
- Issue
- 1
- Pages
- 173-184
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2001718528
- Cited by
- 174
- References
- 0
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.