The DOI matches its Crossref record.
Relationship between blood flow to ischemic regions and extent of myocardial infarction. Serial measurement of blood flow to ischemic regions in dogs.
Abstract
This study was designed to measure early sequential changes in blood flow to ischemic regions after acute coronary occlusion and to determine the relationship between blood flow and the extent of subsequent myocardial infarction. Initial studies were carried out on five dogs which verified using radioisotope-labeled microspheres, 7-10 mum in diameter, to measure changes in blood flow in small myocardial regions after acute coronary artery occlusions. Studies then were carried out on 11 awake dogs chronically prepared with dwelling catheters in the aorta and left atrium and occluders on the left circumflex coronary artery. Microspheres were injected via the left atrial catheter 45 seconds and 2, 6, and 24 hours after complete circumflex coronary occlusion. Six days later myocardial blood flow and the extent of histological infarction were determined for multiple samples from four transmural layers of the entire ischemic zone. Average blood flow to the circumflex region was 0.25 +/- 0.03 (SE), 0.39 +/- 0.05, and 0.53 +/- 0.07 ml/min per g at 45 seconds, and 2, 6, and 24 hours, respectively. When samples from each transmuarl layer were grouped according to increasing ranges of blood flow, the extent of infarction in each layer was inversely related to blood flow. When samples in the same range of blood flow were compared, the extent of infarction in endocardial samples exceeded that in epicardial samples. These data indicate that the relationship between a given measurement of regional blood flow after acute coronary occlusion and the extent of subsequent myocardial infarction varies in different transmural layers and is a function of the time after occlusion that blood flow is measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Regulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
Self-citationReimer, K. A., Jennings, R. B., Cobb, F. R., Murdock, R. H., Greenfield, J. C., Becker, L. C., Bulkley, B. H., Hutchins, G. M., Schwartz, R. P., & Bailey, K. R. (1985) · Circulation Research · doi:10.1161/01.res.56.5.651 · Cited by 358
Self-citationRERYCH, S. K., SCHOLZ, P. M., NEWMAN, G. E., SABISTON, D. C., & JONES, R. H. (1978) · Annals of Surgery · doi:10.1097/00000658-197805000-00002 · Cited by 287
Metadata
- Authors
- Rivas, F., Cobb, F. R., Bache, R. J., & Greenfield, J. C.
- Venue
- Circulation Research
- Published
- 1976-05
- Volume
- 38
- Issue
- 5
- Pages
- 439-447
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2152928050
- Cited by
- 199
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between blood flow to ischemic regions and extent of myocardial infarction. Serial measurement of blood flow to ischemic regions in dogs. https://app.cochat.ai/papers/10.1161/01.res.38.5.439
- The paper
- Rivas, F., Cobb, F. R., Bache, R. J., & Greenfield, J. C. (1976). Relationship between blood flow to ischemic regions and extent of myocardial infarction. Serial measurement of blood flow to ischemic regions in dogs. Circulation Research. https://doi.org/10.1161/01.res.38.5.439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.