Circus movement in rabbit atrial muscle as a mechanism of tachycardia. III. The "leading circle" concept: a new model of circus movement in cardiac tissue without the involvement of an anatomical obstacle.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
SUMMARY In small pieces of rabbit atrial myocardium, sustained periods of circus movement tachycardia were produced by the induction of a single properly timed premature impulse. By use of multiple intracellular and extracellular electrodes the spread of activation during the tachycardia could be analyzed accurately. Because in the present experiments there was no gross anatomical obstacle for the impulse to circulate around, we paid special attention to phenomena occurring in the center of the circus movement. We found that in the absence of an inexcitable central obstacle the center of a circus movement was invaded by multiple centripetal wavelets which converged in the very center of the circuit. On the basis of these observations we developed a new model of circulating excitation in cardiac tissue. The properties of this model (referred to as the "leading circle concept") were compared with the behavior of circus movement around the anatomical obstacle. It turned out that both types of circus movement tachycardia responded differently to changes in basic electrophysiological properties such as conduction velocity and refractory period. For example, addition of carbamylcholine to the tissue bath caused a marked acceleration of the leading circle tachycardia, whereas circus movement in a ring of atrial tissue was hardly affected. On the other hand, depression of conduction velocity by exposure to moderate concentrations of tetrodotoxin had a more pronounced effect on circus movement in the ring preparations than on tachycardias based on a leading circle mechanism. Finally we suggest the use of the strength-interval curve —after some modification —to describe and
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the multiple wavelet hypothesis o f atrial fibrillation.
Moe, G. K. (1962) · Medical Entomology and Zoology · Cited by 913
The Mechanism and Graphic Registration of the Heart Beat.
(1925) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1925.02670230064033 · Cited by 818
On dynamic equilibrium in the heart
Mines, G. R. (1913) · The Journal of Physiology · doi:10.1113/jphysiol.1913.sp001596 · Cited by 735
Circus movement in rabbit atrial muscle as a mechanism of trachycardia.
Allessie, M. A., BONKE, F. I. M., & Schopman, F. J. G. (1973) · PubMed · Cited by 686
Self-citationAllessie, M. A., Bonke, F. I., & Schopman, F. J. (1976) · Circulation Research · doi:10.1161/01.res.39.2.168 · Cited by 477
Self-citationRefractory Period of the Dog's Ventricular Myocardium Following Sudden Changes in Frequency
JANSE, M. J., VAN DER STEEN, A. B. M., VAN DAM, R. T., & DURRER, D. (1969) · Circulation Research · doi:10.1161/01.res.24.2.251 · Cited by 188
SILENT DISSECTION OF THE AORTA
Hoskin, J., & Gardner, F. (1946) · Heart · doi:10.1136/hrt.8.3.141 · Cited by 46
Effect of temperature on pacemaker activity of rabbit sinus node
Yamagishi, S., & Sano, T. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.212.4.829 · Cited by 41
The effect of heart rate on the membrane responsiveness of rabbit atrial muscle
Pasmooij, J. H., van Enst, G. C., Bouman, L. N., Allessie, M. A., & BONKE, F. I. M. (1976) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00585882 · Cited by 20
Self-citationFrequency, Conduction Velocity and Rate of Depolarization in Rabbit Auricle
Viersma, J. W., Bouman, L. N., & MATER, M. (1968) · Nature · doi:10.1038/2171176a0 · Cited by 15
Cited by
Pattern formation outside of equilibrium
Cross, M. C., & Hohenberg, P. C. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.851 · Cited by 7,859
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
New ideas about atrial fibrillation 50 years on
Nattel, S. (2002) · Nature · doi:10.1038/415219a · Cited by 1,481
The surgical treatment of atrial fibrillation
Cox, J. L., Schuessler, R. B., D’Agostino, H. J., Stone, C. M., Chang, B.-C., Cain, M. E., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36684-x · Cited by 1,464
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
“Reentrant mechanisms Stable mother wave macroreentrant (73, 370, 430) Multiple wavelets (7, 386, 388, 509) Stable mother wave microreentrant (356, 509) Unstable reentry circuits (307) Leading circle (5) Rotor (fixed, wandering) (356, 474, 525) Cellular proarrhythmic mechanisms (automaticity/triggered activity) Automat…”
Background
Metadata
- Authors
- Allessie, M. A., Bonke, F. I., & Schopman, F. J.
- Venue
- Circulation Research
- Published
- 1977-07
- Volume
- 41
- Issue
- 1
- Pages
- 9-18
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2106649982
- Cited by
- 1,066
- References
- 10
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.