The distribution of blood rheological parameters in the microvasculature of cat mesentery.
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In vivo studies of the rheological behavior of blood in the microcirculation were conducted by direct in situ measurements in cat mesentery. Upstream to downstream pressure drops were measured in unbranched arterioles, capillaries, and venules, with diameters from 7 to 58 micrometer. Simultaneous measurements of red cell velocity and vessel geometry facilitated computation of bulk velocity, pressure gradient, apparent viscosity, wall shear stress, and resistance. Arteriovenous distributions of these parameters revealed the following. Maximum pressure gradient (0.015 cm H20/micrometer) occurs in the true capillaries (7 micrometer in diameter); intravascular wall shear stress averaged 47.1 dynes/cm2 in arterioles and 29.0 dynes/cm2 in venules. Extreme values as great as 200 dynes/cm2 were observed in a few shunting arterioles. Apparent viscosity averaged 3.59 cP in arterioles, 5.15 cP in venules, and 4.22 cP overall. Intravascular resistance per unit length of microvessel varied with luminal diameter as a power law function with exponents of -4.04 for arterioles, -3.94 for venules, and -3.99 for all vessels combined. This apparent maintenance of Poiseuille's law is attributed to the opposing processes of hematocrit reduction and decreasing shear rate as blood is dispersed in successive arteriolar segments, and the converse action of these processes in the venous confluences which lessen the extent of network variations in apparent viscosity. Reductions in bulk velocity from the normal flow state to below 0.5 mm/sec resulted in increases in apparent viscosity by a factor of 2 to 10, which are attributed primarily to obstruction of the lumen by leukocyte-endothelium adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
FRY, D. L. (1968) · Circulation Research · doi:10.1161/01.res.22.2.165 · Cited by 1,238
THE SUSPENSION STABILITY OF THE BLOOD
Fåhraeus, R. (1929) · Physiological Reviews · doi:10.1152/physrev.1929.9.2.241 · Cited by 938
A flow equation for pigment-oil suspensions of the printing ink type
Casson, N. (1959) · Medical Entomology and Zoology · Cited by 794
Hemolysis and Related Phenomena
(1949) · Journal of the American Medical Association · doi:10.1001/jama.1949.02900200060044 · Cited by 763
Whittaker, S. R. F., & Winton, F. R. (1933) · The Journal of Physiology · doi:10.1113/jphysiol.1933.sp003009 · Cited by 349
Biostatistics: An Introductory Text
King, L. S. (1964) · JAMA · doi:10.1001/jama.1964.03070070063037 · Cited by 324
Barbee, J. H., & Cokelet, G. R. (1971) · Microvascular Research · doi:10.1016/0026-2862(71)90002-1 · Cited by 263
Microvascular measurements by video image shearing and splitting
Intaglietta, M., & Tompkins, W. R. (1973) · Microvascular Research · doi:10.1016/0026-2862(73)90042-3 · Cited by 252
Pressure measurements in the mammalian microvasculature
Intaglietta, M., Pawula, R. F., & Tompkins, W. R. (1970) · Microvascular Research · doi:10.1016/0026-2862(70)90009-9 · Cited by 204
Zweifach, B. W. (1974) · Circulation Research · doi:10.1161/01.res.34.6.858 · Cited by 166
Self-citationNetwork analysis of microcirculation of cat mesentery
Lipowsky, H. H., & Zweifach, B. W. (1974) · Microvascular Research · doi:10.1016/0026-2862(74)90038-7 · Cited by 157
Self-citation
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
The History of Poiseuille's Law
Sutera, S. P., & Skalak, R. (1993) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.25.010193.000245 · Cited by 957
“As a direct proof of the extent of applicability of Poiseuille's law to the in vivo flow of blood, a summary of measurements due to Lipowsky et al (1978) is shown in Figure 5.”
Method(2005) · PubMed · Cited by 567
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Shear stress and the endothelium
Ballermann, B. J., Dardik, A., Eng, E., & Liu, A. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.06720.x · Cited by 439
Metadata
- Authors
- Lipowsky, H. H., Kovalcheck, S., & Zweifach, B. W.
- Venue
- Circulation Research
- Published
- 1978-11
- Volume
- 43
- Issue
- 5
- Pages
- 738-749
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2129241682
- Cited by
- 408
- References
- 12
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.