The plasma membrane of leading pacemaker cells in the rabbit sinus node. A qualitative and quantitative ultrastructural analysis.
Open accessThe DOI matches its Crossref record.
Abstract
We studied the fine structure of the plasma membrane of electrophysiologically identified leading pacemaker cells from the rabbit sinus node, using both ultrathin sections of fixed tissue and replicas of freeze-cleaved material. We found that differences exist between sinus node and working myocardial membranes, but these are only quantitative. The caveolae or sarcolemmal invaginations are present in very large numbers; they increase the surface area of the plasma membrane by about 100%. The small macular nexuses that are present represent 0.2% of the membrane surface area. Nexuses are therefore about 10 times less numerous in leading sinus node cells than in working myocardium cells. A single equivalent electrical representation of the sinus node shows, nevertheless, that an appreciable electrical coupling may be expected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Electrophysiological features of the mouse sinoatrial node in relation to connexin distribution
Verheijck, E. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00364-9 · Cited by 172
Transcriptome analysis of mouse and human sinoatrial node cells reveals a conserved genetic program
van Eif, V., Stefanovic, S., van Duijvenboden, K., Bakker, M., Wakker, V., de Gier-de Vries, C., Zaffran, S., Verkerk, A. O., Boukens, B. J., & Christoffels, V. (2019) · Development · doi:10.1242/dev.173161 · Cited by 76
Ultrastructure of electrophysiologically identified human sinoatrial nodes
Lowe, J. E., Hartwich, T., Takla, M., & Schaper, J. (1988) · Basic Research in Cardiology · doi:10.1007/bf02005826 · Cited by 25
Metadata
- Authors
- Masson-Pévet, M., Bleeker, W. K., & Gros, D.
- Venue
- Circulation Research
- Published
- 1979-11
- Volume
- 45
- Issue
- 5
- Pages
- 621-629
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2067669648
- Cited by
- 82
- References
- 0
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The plasma membrane of leading pacemaker cells in the rabbit sinus node. A qualitative and quantitative ultrastructural analysis. https://app.cochat.ai/papers/10.1161/01.res.45.5.621
- The paper
- Masson-Pévet, M., Bleeker, W. K., & Gros, D. (1979). The plasma membrane of leading pacemaker cells in the rabbit sinus node. A qualitative and quantitative ultrastructural analysis. Circulation Research. https://doi.org/10.1161/01.res.45.5.621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.