Inhibitors of oxidative ATP production cause transient vasoconstriction and block subsequent pressor responses in rat lungs.
The DOI matches its Crossref record.
Abstract
We wondered if depression of oxidative adenosine triphosphate (ATP) production caused pulmonary vasoconstriction. If so, then several chemically different inhibitors of oxidative ATP production all should cause pulmonary pressor responses. The vascular reactivity of isolated, blood-perfused rat lungs was established by eliciting pressor responses to airway hypoxia and to intraarterial angiotensin II. Then, during normoxia, we added to perfusate one of five chemical inhibitors of oxidative ATP production: 10 mM azide, 1 mM cyanide, 1 mM dinitrophenol, 5 or 10 microM antimycin A, or 0.5 microM rotenone. Each of the five chemical inhibitors, but not their solvents, caused a transient pressor response, followed by loss of vascular reactivity to hypoxia, angiotensin II, and chemical inhibitors. The inhibitor pressor responses were not due to an effect on blood cells, since they also were seen in lungs perfused with plasma. The magnitudes of pressor responses to all metabolic inhibitors except azide correlated with the magnitudes of preceding pressor responses to hypoxia, but not to the preceding angiotensin II responses. When verapamil or calcium chloride was added to perfusate, the hypoxic and inhibitor pressor responses were blunted more than was the angiotensin II response. Thus, five chemically different substances, inhibiting different steps of oxidative ATP production, all caused pressor responses that were blocked readily by verapamil and by increased perfusate calcium chloride. These results support the possibility that depression of oxidative ATP production elicits pulmonary vasoconstriction that is dependent on influx of extracellular calcium. Hypoxia might also be sensed in the pulmonary circulation by decreased oxidative ATP production in some as yet unidentified lung cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Hypoxic Pulmonary Vasoconstriction
Dunham-Snary, K. J., Wu, D., Sykes, E. A., Thakrar, A., Parlow, L. R. G., Mewburn, J. D., Parlow, J. L., & Archer, S. L. (2017) · Chest · doi:10.1016/j.chest.2016.09.001 · Cited by 510
Hypoxic pulmonary vasoconstriction
Moudgil, R., Michelakis, E. D., & Archer, S. L. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00733.2004 · Cited by 454
Model for Hypoxic Pulmonary Vasoconstriction Involving Mitochondrial Oxygen Sensing
Waypa, G. B., Chandel, N. S., & Schumacker, P. T. (2001) · Circulation Research · doi:10.1161/hh1201.091960 · Cited by 367
Archer, S. L., Gomberg-Maitland, M., Maitland, M. L., Rich, S., Garcia, J. G. N., & Weir, E. K. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01324.2007 · Cited by 366
A redox-based O2 sensor in rat pulmonary vasculature.
Archer, S. L., Huang, J., Henry, T., Peterson, D., & Weir, E. K. (1993) · Circulation Research · doi:10.1161/01.res.73.6.1100 · Cited by 362
Waypa, G. B., Marks, J. D., Mack, M. M., Boriboun, C., Mungai, P. T., & Schumacker, P. T. (2002) · Circulation Research · doi:10.1161/01.res.0000036751.04896.f1 · Cited by 285
Patel, A. J. (1997) · The EMBO Journal · doi:10.1093/emboj/16.22.6615 · Cited by 277
O 2 sensing is preserved in mice lacking the gp91 phox subunit of NADPH oxidase
Archer, S. L., Reeve, H. L., Michelakis, E., Puttagunta, L., Waite, R., Nelson, D. P., Dinauer, M. C., & Weir, E. K. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.14.7944 · Cited by 263
Regulation of hypoxic pulmonary vasoconstriction: basic mechanisms
Sommer, N., Dietrich, A., Schermuly, R. T., Ghofrani, H. A., Gudermann, T., Schulz, R., Seeger, W., Grimminger, F., & Weissmann, N. (2008) · European Respiratory Journal · doi:10.1183/09031936.00013908 · Cited by 213
Evans, A. M., Mustard, K. J. W., Wyatt, C. N., Peers, C., Dipp, M., Kumar, P., Kinnear, N. P., & Hardie, D. G. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m510040200 · Cited by 186
Paddenberg, R., Ishaq, B., Goldenberg, A., Faulhammer, P., Rose, F., Weissmann, N., Braun-Dullaeus, R. C., & Kummer, W. (2003) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00149.2002 · Cited by 184
“This interpretation, however, is difficult to match with the observation that rotenone, which is generally accepted to decrease mitochondrial ROS production in vascular cells, shares the transient pulmonary vasoconstrictor effect with antimycin A (29), and direct measurements have shown that antimycin A reduces normox…”
Hypoxic pulmonary vasoconstriction: redox events in oxygen sensing
Waypa, G. B., & Schumacker, P. T. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00722.2004 · Cited by 166
MICHELAKIS, E. (2004) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2004.09.007 · Cited by 165
“The evidence suggesting that the mitochondrial ETC could be important in O2 sensing is based in part on the concordant hemodynamic (vasoconstriction) [68] and electrophysiological effects (Kv channel inhibition) [65,69,70] of proximal ETC inhibitors (e.”
BackgroundCalcium, mitochondria and oxygen sensing in the pulmonary circulation
Ward, J. P. T., Snetkov, V. A., & Aaronson, P. I. (2004) · Cell Calcium · doi:10.1016/j.ceca.2004.02.017 · Cited by 45
Metadata
- Authors
- Rounds, S., & McMurtry, I. F.
- Venue
- Circulation Research
- Published
- 1981-03
- Volume
- 48
- Issue
- 3
- Pages
- 393-400
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2132623108
- Cited by
- 103
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.